Adjustment and Operation
•Turn the power on after connecting a load.
Otherwise it can cause excess current causing instantaneous breakage of the Pressure switch.
•Do not short-circuit the load.
Although error is displayed when the Pressure switch load is short circuit, generated excess current lead to cause
the damage of the Pressure switch.
•Do not press the setting buttons with a sharp pointed object.
It may damage the setting buttons.
•If using the product to detect very small pressure rates, warm up the product for 10 to 15 minutes first.
There will be a drift on the display of approximate 1% immediately after the power supply is turned on, within 10
minutes.
•Perform settings suitable for the operating conditions.
Incorrect setting can cause operation failure.
For details of each setting, refer to page
•Do not touch the LCD during operation.
The display can vary due to static electricity.
Maintenance
•Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of
air before performing maintenance.
There is a risk of unexpected malfunction.
•Perform regular maintenance and inspections.
There is a risk of unexpected malfunction.
•Perform drainage regularly.
If condensate enters the secondary side, it can cause operating failure of pneumatic equipment.
•Do not use solvents such as benzene, thinner etc. to clean the Pressure switch.
They could damage the surface of the body and erase the markings on the body.
Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully
squeezed, then wipe up the stains again with a dry cloth.
25
to
67
of this manual.
-9-
No.PS※※-OMU0009-F