Download Print this page

Eldat RCJ31 Manual page 2

Flush-mounted receiver 230v normally open

Advertisement

SETTING UP THE RECEIVER
The receiver must be installed and commissioned by a qualified electrician in a 
commercially available flush-mounted installation box (min. diameter 68 mm).
1. Switch off the power supply.
2. Connect the supply voltage and the devices to
be controlled according to the wiring diagram.
Observe the applicable electrical regulations.
PROGRAMMING
Program transmitters
The RCJ31 only responds to programmed Easywave transmitters. In order to program a transmitter,
activate the programming mode for the required operation type, then press the transmitter button to be
programmed. If an already programmed transmitter is programmed again, the previous operation type
is overwritten by the new selection. Up to 32 transmission codes can be programmed.
The external button uses up one memory slot, as soon as it gets programmed into another than the
default operation mode.
Operation
(1)
Indication
[Press button]
ON/OFF
2-TB
P
1x briefly
LED P flashes red
Tx
Transmitter
LED P lights up
button
2 seconds red
1x briefly
LOGIC
2-TB
P
1x briefly
LED P flashes red
P
1x long
LED P flashes green
Tx
Transmitter
LED P lights up
button
2 seconds green
1x briefly
ON/OFF
1-TB
P
2x briefly
LED P flashes red
Tx
Transmitter
LED P lights up
button
2 seconds red
1x briefly
DEAD MAN
1-TB
P
2x briefly
LED P flashes red
P
1x long
LED P flashes green
Tx
Transmitter
LED P lights up
button
2 seconds green
1x briefly
TIMER
1-TB
P
3x briefly
LED P flashes red
Tx
Transmitter
LED P lights up
button
2 seconds red
1x briefly
Set TIMER
P
3x briefly
LED P flashes red
P
1x long
LED P lights up green
EXPLANATION
LED indications
lights up
off
flashes
flashes quickly
2
3. Transfer the coding of the transmitter buttons
to the receiver (see „Program transmitters").
4. Seal the flush-mounted installation box with
the corresponding cover.
Note
Operating mode ON/OFF 2-TB selected
Transmission code is programmed.
When the LED turns off, the receiver
is ready for operation.
Operating mode ON/OFF 2-TB
Operating mode LOGIC selected
Transmission code is programmed.
When the LED turns off, the receiver
is ready for operation.
Operating mode ON/OFF 1-TB selected
Transmission code is programmed.
When the LED turns off, the receiver
is ready for operation.
Operating mode ON/OFF 1-TB
Operating mode Dead Man selected
Transmission code is programmed.
When the LED turns off, the receiver
is ready for operation.
Operating mode TIMER 1-TB selected
Transmission code is programmed.
When the LED turns off, the receiver
is ready for operation.
(default setting: 7 minutes)
Operating mode TIMER selected
set TIMER (see page 3)
Press button
briefly (< 2 s) = Press button for less than 2 seconds
long (> 2 s)
= Press button longer than 2 seconds
The cable length for connecting external
buttons must not exceed 3 meters.
Make sure there is no interference with the
wireless connection!
Do not mount the device in a distribution box,
in metal casings and in direct proximity to lar-
ge metal objects.
Programming structure
Programming level 1
Ready for operation
P < 2 s
ON/OFF
2-TB
P < 2 s
P > 2 s
ON/OFF
1-TB
P < 2 s
P > 2 s
TIMER
1-TB
P < 2 s
P > 2 s
Ready for operation
P
c
Select operating mode
Send transmission code
Tx
d
A programming process can be cancelled by
briefly pressing the P programming button
several times. Once the LED turns off, the
receiver returned to standby.
Operation
1-TB = 1-button operation
2-TB = 2-button operation
Programming level 2
LOGIC
2-TB
DEAD MAN
1-TB
Set
TIMER