Summary of Contents for IFM Electronic efector 200 O4H5 Series
Page 1
All manuals and user guides at all-guides.com Operating instructions Diffuse reflection sensor with background suppression O4H5xx...
Page 2
All manuals and user guides at all-guides.com 1 Preliminary note 1.1 Symbols used ► Instruction > Reaction, result […] Designation of pushbuttons, buttons or indications → Cross-reference Important note Non-compliance can result in malfunctions or interference. 2 Functions and features The diffuse reflection sensor detects objects and materials without contact and indicates their presence by a switching signal.
Page 3
All manuals and user guides at all-guides.com Note: The objects to be detected are to move transversely to the lens of the sensor. ► In case of other directions of movement it should be tested before whether safe switching is guaranteed. 4 Electrical connection The unit must be connected by a qualified electrician.
Page 4
All manuals and user guides at all-guides.com 5 Settings 5.1 Sensitivity setting The sensor is to switch when the object is detected ► Position the object. ► Press [OUT on] for 2 s. > The sensitivity is set to the object. The LED flashes. ►...
Page 5
All manuals and user guides at all-guides.com Possible causes • Insufficient difference in measurements • Max. programming time of 15 min. exceeded 5.4 Electronic lock The unit can be locked electronically to prevent unauthorised setting. On delivery the unit is not locked. ►...