Current Program Setting With External Voltage (Input Voltage: 0 To 10Vdc); Current Program Setting With External Voltage (Input Voltage: 0 To 5Vdc) - Matsusada Precision PVCE Series Instruction Manual

Hide thumbs Also See for PVCE Series:
Table of Contents

Advertisement

8-5-5

Current Program Setting with External Voltage (Input voltage: 0 to 10Vdc)

・ Check that the mode set in the current setting is Remote mode.
Refer to [8-4 Local/Remote Mode Switching (Voltage Setting, Current Setting)] on page 65.
・ The output current is set with an external voltage.
Set "E.Cur" to "Volt" and "I.Con" to "10V" in ["EXtCont": Remote Programming Settings] of the
Start-up menu.
(Input voltage 0 to 10Vdc corresponds to 0 to 100% of rated current output.)
Internal circuit
-S
(Common)
8-5-6

Current Program Setting with External Voltage (Input voltage: 0 to 5Vdc)

・ Check that the mode set in the current setting is Remote mode.
Refer to [8-4 Local/Remote Mode Switching (Voltage Setting, Current Setting)] on page 65.
・ The output current is set with an external voltage.
Set "E.Cur" to "Volt" and "I.Con" to "5V" in ["EXtCont": Remote Programming Settings] of the Start-up
menu.
(Input voltage 0 to 5Vdc corresponds to 0 to 100% of rated current output.)
Internal circuit
-S
(Common)
TB1
External connection
5
0 to 10Vdc
+
2
TB1
External connection
5
0 to 5Vdc
+
2
69
Matsusada Precision PVCE/PVCEJ series
8 Analog Control

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVCE Series and is the answer not in the manual?

This manual is also suitable for:

Pvcej series

Table of Contents