8-5-5
Current Program Setting with External Voltage (Input voltage: 0 to 10Vdc)
・ Check that the mode set in the current setting is Remote mode.
Refer to [8-4 Local/Remote Mode Switching (Voltage Setting, Current Setting)] on page 65.
・ The output current is set with an external voltage.
Set "E.Cur" to "Volt" and "I.Con" to "10V" in ["EXtCont": Remote Programming Settings] of the
Start-up menu.
(Input voltage 0 to 10Vdc corresponds to 0 to 100% of rated current output.)
Internal circuit
-S
(Common)
8-5-6
Current Program Setting with External Voltage (Input voltage: 0 to 5Vdc)
・ Check that the mode set in the current setting is Remote mode.
Refer to [8-4 Local/Remote Mode Switching (Voltage Setting, Current Setting)] on page 65.
・ The output current is set with an external voltage.
Set "E.Cur" to "Volt" and "I.Con" to "5V" in ["EXtCont": Remote Programming Settings] of the Start-up
menu.
(Input voltage 0 to 5Vdc corresponds to 0 to 100% of rated current output.)
Internal circuit
-S
(Common)
TB1
External connection
5
0 to 10Vdc
+
2
TB1
External connection
5
0 to 5Vdc
+
2
69
Matsusada Precision PVCE/PVCEJ series
8 Analog Control