Matsusada Precision PVCE Series Instruction Manual

Hide thumbs Also See for PVCE Series:
Table of Contents

Advertisement

Quick Links

Instruction Manual
PVCE/PVCEJ series
Model
*268.9.004*
B/N:268.9.004
Rev 0.0
F-RA-001-3
R2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVCE Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Matsusada Precision PVCE Series

  • Page 1 Instruction Manual PVCE/PVCEJ series Model *268.9.004* B/N:268.9.004 Rev 0.0 F-RA-001-3...
  • Page 2 Trademarks ◆ Company names and product names in this document are the trademarks or registered trademarks of their respective companies.
  • Page 3 Indicates that it must be performed Bistable push button switch on in order to demonstrate the performance of the product. Protective earth terminal (ground terminal for electric shock Bistable push button switch off prevention) Ground terminal Alternative Current Matsusada Precision PVCE/PVCEJ series...
  • Page 4 If the product does not have a fuse holder externally, the user cannot replace the fuse. If the fuse blows out, do not open the case or panel. Please contact our sales representative. ◆ Do not modify or damage the cable. It may cause electric shock and fire. Matsusada Precision PVCE/PVCEJ series...
  • Page 5 There is a capacitor at the terminal, and it is particularly dangerous to touch it immediately after turning off the power supply. Be careful of the electric charge of these capacitors and connect it to earth to discharge it completely. Remove input line (AC line) during work. Matsusada Precision PVCE/PVCEJ series...
  • Page 6 For replacement, please contact our sales office (replacement require separate repair charges). Do not exchange fans with other users because there is a danger of electric shock, etc. Matsusada Precision PVCE/PVCEJ series...
  • Page 7: Table Of Contents

    Inductive Load ....................... 4-3-4 When Connecting a Load with Electrical Discharge ..........4-3-5 When Connecting a Load with Accumulated Energy ..........4-3-6 Connecting Load Wires ..................4-3-7 Grounding Ouput Terminals .................. 4-3-8 Attaching the Output Terminal Cover ..............Matsusada Precision PVCE/PVCEJ series...
  • Page 8 Current Program Setting with External Voltage (Input voltage: 0 to 5Vdc) 8-5-7 ............Current Program Setting with External Resistance 8-5-8 ............Current Program Setting with External Resistance Monitor and Status Output ....................8-6-1 Monitor Output ...................... 8-6-2 Status Output ......................Matsusada Precision PVCE/PVCEJ series...
  • Page 9 Vcon Programming Control when the –LRcp Option is Installed 11-3-6 ........104 Icon Programming Control when the –LRcp Option is Installed 11-3-7 ........Monitor Output when the –LRcp Option is Installed 11-3-8 ........... 104 Troubleshooting ..........................Matsusada Precision PVCE/PVCEJ series...
  • Page 10 Matsusada Precision PVCE/PVCEJ series...
  • Page 11: Features

    In the constant current mode, the unit maintains the set output current even if the load varies. These two modes do not function simultaneously. Refer to [6-1-3 Crossover Mode] on page 31. It always works in either mode. Matsusada Precision PVCE/PVCEJ series...
  • Page 12: Before Use

    When you change the initial settings such as the boot menu, be sure to restart the unit. If it is not restarted, the settings may not be reflected correctly. ・ Before changing loads, turn off all equipment consisting of your system. Matsusada Precision PVCE/PVCEJ series...
  • Page 13: Installation

    2-5-4 Bias When using the output in the floating (bias) state with respect to the ground, the maximum voltage is 250 Vdc. Be careful because a bias voltage is generated at the output terminal. Matsusada Precision PVCE/PVCEJ series...
  • Page 14: Specifications

    The voltage, current, and power shown in the table are output to the output terminals of the unit. Never touch the output and sense terminals while the unit is running or just after turning it off. Matsusada Precision PVCE/PVCEJ series...
  • Page 15 The voltage, current, and power shown in the table are output to the output terminals of the unit. Never touch the output and sense terminals while the unit is running or just after turning it off. Matsusada Precision PVCE/PVCEJ series...
  • Page 16: Input Specifications

    POWER switch. ✽ When the POWER switch repeatedly turns ON/OFF at short intervals, "ACF/E07" ACF (low input voltage) may be displayed to protect the internal circuit. Matsusada Precision PVCE/PVCEJ series...
  • Page 17: Installation Environment

    *2 PVCEJ and PVCE 1U 750 to 800W comply with it. *3 PVCEJ and PVCE 1U 750 to 2.5kW comply with it. *4 PVCE 2U 3.2 to 5.5 kW and PVCE 3U 7.5 to 10kW/15kW comply with it. Matsusada Precision PVCE/PVCEJ series...
  • Page 18: External View

    ⑦ ⑭ Functional grounding terminal Sensing terminal (for local) For models with an output voltage of 300V or higher, the terminal is integrated into the output terminal connector. Refer to [10 Multi-digital Interface] on page 84. Matsusada Precision PVCE/PVCEJ series...
  • Page 19 RS-485 interface ⑥ ⑭ Functional grounding terminal Sensing terminal (for remote) ⑦ Sensing terminal (for local) NSC (Not Sink Current) ON/OFF ⑮ ⑧ switch Connector for remote interface (TB1) Refer to [10 Multi-digital Interface] on page 84. Matsusada Precision PVCE/PVCEJ series...
  • Page 20: Pvcej External Dimensions

    3 Specifications 3-5-3 PVCEJ External Dimensions 16V or lower models (Output shape: Bus bar) 20V or higher models (Output shape: Terminal block) 300V or higher models (Output shape: Connector) Matsusada Precision PVCE/PVCEJ series...
  • Page 21: Pvce 1U 750 To 800W External Dimensions

    3 Specifications 3-5-4 PVCE 1U 750 to 800W External Dimensions 16V or lower models (Output shape: Bus bar) 20V or higher models (Output shape: Terminal block) Matsusada Precision PVCE/PVCEJ series...
  • Page 22 3 Specifications 300V or higher models (Output shape: Connector) Matsusada Precision PVCE/PVCEJ series...
  • Page 23: Pvce 1U 1.3 To 1.6Kw/1.8 To 2.5Kw External Dimensions

    3 Specifications 3-5-5 PVCE 1U 1.3 to 1.6kW/1.8 to 2.5kW External Dimensions 80V or lower models (Output shape: Bus bar) 100V or higher models (Output shape: Terminal block) Matsusada Precision PVCE/PVCEJ series...
  • Page 24: Pvce 2U 3.2 To 3.6Kw/4.8 To 5.5Kw External Dimensions

    3 Specifications 3-5-6 PVCE 2U 3.2 to 3.6kW/4.8 to 5.5kW External Dimensions 20V or lower models (Output shape: Big bus bar) 80V or lower models (Output shape: Small bus bar) Matsusada Precision PVCE/PVCEJ series...
  • Page 25 3 Specifications 100V or higher models (Output shape: Terminal block) Matsusada Precision PVCE/PVCEJ series...
  • Page 26: Pvce 3U 7.5 To 10Kw/15Kw External Dimensions

    3 Specifications 3-5-7 PVCE 3U 7.5 to 10kW/15kW External Dimensions 15V or lower models (Output shape: Big bus bar) 250V or lower models (Output shape: Small bus bar) Matsusada Precision PVCE/PVCEJ series...
  • Page 27 3 Specifications 300V or higher models (Output shape: Terminal block) 800V or higher models (Output shape: Terminal block) Matsusada Precision PVCE/PVCEJ series...
  • Page 28: Wiring

    1.8 to 2.5 kW models with -L (3P) option ・ 3.2 to 5.5kW * including -L (1P) and -L (400V) <Recommended troidal cores> ・ Model: HF70T31×13×19 (TDK Corp.) ・ Model: LRF462725MKX (Nippon Chemi-Con Corp.) ・ or equivalents Matsusada Precision PVCE/PVCEJ series...
  • Page 29: Connecting Ac Input Power Cable For Single-Phase

    Connect the AC input power cable to the AC input connector on the rear panel matching with the indication on the terminal. L1 L2 L3 M4 screws Tightening torque: 1.4 N·m L1 L2 L3 M6 screws Tightening torque: 3.0 N·m Models for 5.5kW or lower Models for 7.5kW or higher Matsusada Precision PVCE/PVCEJ series...
  • Page 30: Connecting The Load

    <Recommended Cores for use in EMC measures> ・ Model: HS52 (TDK Corp.) ・ Model: ACS-63 (Kuretake Denko Co., Ltd.) ・ Model: M-3854-01 (Ozeki Co., Ltd.) ・ or equivalents Matsusada Precision PVCE/PVCEJ series...
  • Page 31: Connecting The Load In Parallel

    If the repetition period of short-circuiting and opening is faster than about one second, smoke or liquid leakage may occur on the unit. In that case, avoid using the unit and contact us. Matsusada Precision PVCE/PVCEJ series...
  • Page 32: When Connecting A Load With Accumulated Energy

    3. Use a diode with little loss. ・ Consider the heat generated by a diode. If the heat dissipation is insufficient, the diode will burn out. ・ A diode cannot be used together with the remote sensing function. Matsusada Precision PVCE/PVCEJ series...
  • Page 33: Connecting Load Wires

    1.3 to 5.5kW Terminal block of M6 3.0 N·m Output voltage: 100V to 650V 7.5 to 15kW Output voltage: 300V to 650V 7.5 to 15kW Terminal block of M4 1.4 N·m Output voltage: 800V to 1500V Matsusada Precision PVCE/PVCEJ series...
  • Page 34: Grounding Ouput Terminals

    Do ground the - output terminal when a model whose output voltage exceeds 650V is used. When the output of the unit is floated to use, it may result in electric shock on the front panel, CO-M cable connection connectors (IN) and (OUT), and LAN, USB, and RS-485 ports. Matsusada Precision PVCE/PVCEJ series...
  • Page 35: Attaching The Output Terminal Cover

    Models with 750 to 800W and output voltage300V to 650V Pull out the load lines through the hole in the output terminal cover. Fix them with the supplied screws. (Tightening torque: 0.44 to 0.8 N·m) Output terminal cover M3 screws Matsusada Precision PVCE/PVCEJ series...
  • Page 36: Connecting The Sensing Lines

    Sensing terminal (for remote) Sensing terminal (for remote) Between “ “ and “ S” are Sensing terminal (for local) –S -OUT +S +OUT short-circuited. It is connected to the “ ” output terminal internally. Matsusada Precision PVCE/PVCEJ series...
  • Page 37: Specifications Of Sensing Terminals

    In such a case, connect an electrolytic capacitor to the sensing terminals on the load side as necessary to stabilize the output. Select an electrolytic capacitor with care not to exceed the rated voltage. Matsusada Precision PVCE/PVCEJ series...
  • Page 38: Connector (Tb1) For The Remote Interface

    Even if the TB1 is not used, the remote connector cover should be attached to ensure safety. Remote connector cover Connector (TB1) for the remote interface Cable clamp Clamp fixing screw M3 Male connector for D-Sub 25-pin Screw lock M2.6 Cover fixing nut M3 Cover fixing screw M3 Matsusada Precision PVCE/PVCEJ series...
  • Page 39: Pin Numbers And Applications

    Although PIN 6, 11, 12, 13, and 19 are isolated from the other PINs, in order to comply with the safety requirements, take appropriate measures so that everyone cannot touch the TB1 and the circuits connected from TB1 as described above. For details, refer to [8-6-2 Status Output] on page 72. Matsusada Precision PVCE/PVCEJ series...
  • Page 40: Operation To Output

    Set voltage/current values to output. Output volt. setting (VOLTAGE dial) Output curr. setting (CURRENT dial) Press SET SET indicator: ON Starting output Start the output by pressing the OUTPUT switch. OUTPUT indicator: ON Press OUTPUT Matsusada Precision PVCE/PVCEJ series...
  • Page 41: Normal Operation

    For example, in CV mode, if the load fluctuates and the current exceeds the current setting value, it automatically switches from CV mode to CC mode. In CC mode, when the load fluctuates and the load voltage exceeds the setting value, it automatically switches from CC mode to CV mode. Matsusada Precision PVCE/PVCEJ series...
  • Page 42: Output Switch

    When the output is "ON", the preset mode is cleared after approx. 1.3 seconds. Output volt setting (VOLTAGE dial) Output curr setting (CURRENT dial) Press SET SET indicator: ON Setting values for volt. and curr. are displayed for approx. 1.3s. Matsusada Precision PVCE/PVCEJ series...
  • Page 43: Protect Switch

    When outputting without the protection function, use it with care. Overvoltage protection setting (OVP) Rotate the VOLTAGE dial. VOLTAGE Overcurrent protection setting (OCP) Low voltage protection setting (UVP) Low limit voltage setting (UVL) Operating mode change Protection setting (MCP) Protection delay time setting Matsusada Precision PVCE/PVCEJ series...
  • Page 44 ・ UVP will not work until 2 seconds from the start of output plus a delay time. ・ MCP will not work until 0.5 seconds from the start of output plus a delay time. ・ The setting range is from 0.0 to 25.5 seconds. Set it to your desired value. Matsusada Precision PVCE/PVCEJ series...
  • Page 45: Lock Switch

    When the FINE indicator is OFF, the setting value changes by every approx. 1%. Output volt setting (VOLTAGE dial) Output curr. setting (CURRENT dial) Press FINE FINE indicator: ON One count in the volt/curr. can be changed. Matsusada Precision PVCE/PVCEJ series...
  • Page 46: Power Failure Protection

    (The display will return to the previous display from "OtP/E02".) ・ To restart the output, wait until the internal temperature of it has cooled down, then set the OUTPUT switch to "ON". (OUTPUT indicator: ON) Internal temperature increase OTP error OUTPUT: OFF Matsusada Precision PVCE/PVCEJ series...
  • Page 47: Remote Sensing

    ・ If the "+" sensing line and "-" sensing line is connected in reverse, or if the guaranteed sensing voltage is exceeded, the display changes to "Sr/E03" and the output is turned off. ・ To clear the error, press the OUTPUT switch or set the LS (Remote switch) to "OFF". Sensing lines reversely connected Sr error Matsusada Precision PVCE/PVCEJ series...
  • Page 48: Acf (Input Voltage Abnormality)

    UVP (Undervoltage Protection) 6-4 PROTECT Switch ACF/E07 ACF (Input Voltage Abnormality) 6-10 ACF (Input Voltage Abnormality) OCP/E05 OCP(Overcurrent Protection) 6-4 PROTECT Switch MCP/E14 MCP (Operating Mode Change Protection) 6-4 PROTECT Switch Press OUTPUT to clear fault Matsusada Precision PVCE/PVCEJ series...
  • Page 49: Useful Features

    "-" output when both "+" and "-" are used, do not connect other remote switches at the same time. It is unavailable depending on models. For details, refer to [4-3-7 Grounding the Output Terminal] on page 24. Matsusada Precision PVCE/PVCEJ series...
  • Page 50: Sink Current Setting

    The sink current setting cannot stabilize the reverse current by controlling it. When loads such as inductive load or regenerative motor, which the reverse voltage is over the rated voltage, are connected, protect the unit by inserting a dummy resistor or a reverse current prevention diode. Matsusada Precision PVCE/PVCEJ series...
  • Page 51: Master/Slave Setting

    (For parallel connection, refer to [7-1-2 Parallel Operation] on page 39. Regarding master/slave connection Only the same model can be connected. Do not connect units that are different models. Doing so might lead to malfunction or breakdown. Matsusada Precision PVCE/PVCEJ series...
  • Page 52: Master/Slave Connection Diagram

    When using the units as CE marking compatible ones, attach ferrite cores to the CO-M cable. Attach the cores as close as possible to the connectors. <Recommended Ferrite cores> ・ Model: GRFC-10 (Kitagawa Industries Co., Ltd.) ・ or equivalents Matsusada Precision PVCE/PVCEJ series...
  • Page 53: Multiple Setting

    ✽ "a", "b", and "c" is displayed only when each switch, "SET", "LOCK", and "PROTECT" is pressed. Checking memory in use currently can be also done with the flashing interval of the SET indicator. Flashing interval Mode No. Displaying monitor value Displaying preset value Memory "a" Memory "b" Memory "c" Matsusada Precision PVCE/PVCEJ series...
  • Page 54 The SET indicator turns off to indicate the Multiple Setting mode cleared. Press & hold SET indicator: Flashing stop ✽ When the POWER switch is turned on, the Multiple Setting function is restored to the state before the power turned off. Matsusada Precision PVCE/PVCEJ series...
  • Page 55: Start-Up Menu

    Set the ramp function. Unit setting Set the unit number. Master/Slave setting Set master/slave. Command setting Switch SCPI and Matsusada Precision original commands. Int.F Interface setting Switch the standard digital interface and option. Baud rate setting Set the baud rate.
  • Page 56 2. Press and hold the LOCK switch to exit from the menu. Register each setting. Press & hold LOCK ✽ In the Start-up menu, regardless of the displayed item, all items set until pressing and holding the LOCK switch are stored. Matsusada Precision PVCE/PVCEJ series...
  • Page 57: Each Menu Mode

    The CURRENT dial Press SET to change changes protection protection setting: OVP, settings. OCP, or UVP. Press SET To register each setting, press and hold the LOCK switch. Register each setting. Press & hold LOCK Matsusada Precision PVCE/PVCEJ series...
  • Page 58 The CURRENT dial changes On/OFF of LD (Interlock). Change On/OFF of LD (Interlock) with the CURRENT dial during “Ld” displayed To register each setting, press and hold the LOCK switch. Register each setting. Press & hold LOCK Matsusada Precision PVCE/PVCEJ series...
  • Page 59 (* It is set to "On" at the factory shipment.) The CURRENT dial changes On/OFF of Change setting with the Power failure protection. CURRENT dial during “PFP” displayed. To register each setting, press and hold the LOCK switch. Matsusada Precision PVCE/PVCEJ series...
  • Page 60 “V.Con”: Output voltage scale selection (10V(10K)/5V(5K)) “V.Mon”:Output voltage monitor scale selection (10V/5V) (✽ At the factory shipment, the voltage program is set to "Volt", the output voltage scale is set to “10V”, the output voltage monitor scale is set to “10V”.) Matsusada Precision PVCE/PVCEJ series...
  • Page 61 “I.Con”:Output current scale selection (10V(10K)/5V(5K)) “I.Mon”:Output current monitor scale selection(10V/5V) (✽ At the factory shipment, the current program is set to "Volt", the output current scale is set to “10V”, the output voltage monitor scale is set to “10V”.) Matsusada Precision PVCE/PVCEJ series...
  • Page 62 1.0sec when the Start-up menu is registered. However, the time of 0.0sec can be set at "aOn", "bOn", and "cOn". The VOLTAGE dial changes ON time. The CURRENT dial changes each ON output time. Press SET to change Press each ON time. Matsusada Precision PVCE/PVCEJ series...
  • Page 63 "m" : Set the time setting unit for the pulse sequence function to Min (minute). "h" : Set the time setting unit for the pulse sequence function to Hour (hour). Press & hold PROTECT Press & hold PROTECT Press & hold PROTECT Matsusada Precision PVCE/PVCEJ series...
  • Page 64 ✽ When "0" is set, the repeat count is set to infinite. The CURRENT dial changes repeat count. Press LOCK to change Press repeat count. LOCK To register each setting, press and hold the LOCK switch. Register each setting. Press & hold LOCK Matsusada Precision PVCE/PVCEJ series...
  • Page 65 0.0sec when the Start-up menu is registered. The VOLTAGE dial switches ON ramp time items. The CURRENT dial changes each ON ramp time. Press SET to change each Press ON ramp time. Matsusada Precision PVCE/PVCEJ series...
  • Page 66 "m" : Set the time setting unit in the ramp function to Min (minute). "h" : Set the time setting unit in the ramp function to Hour (hour). Press & hold PROTECT Press & hold PROTECT Press & hold PROTECT Matsusada Precision PVCE/PVCEJ series...
  • Page 67 The CURRENT dial changes the unit No. Change the setting (from 0 to 31) with the CURRENT dial during “Unt” displayed. To register each setting, press and hold the LOCK switch. Register each setting. Press & hold LOCK Matsusada Precision PVCE/PVCEJ series...
  • Page 68 Turn the CURRENT dial to switch to Local or Remote at slave. The CURRENT dial changes Local/Remote. Press SET to change Local/Remote at slave mode. Press To register each setting, press and hold the LOCK switch. Register each setting. Press & hold LOCK Matsusada Precision PVCE/PVCEJ series...
  • Page 69 The CURRENT dial changes Int.F (interface) function: 232, Opt, LAN, and Changes settings with the CURRENT dial during “Int.F” displayed. To register each setting, press and hold the LOCK switch. Register each setting. Press & hold LOCK Matsusada Precision PVCE/PVCEJ series...
  • Page 70 ✽ It is displayed only when "Int.F" is set to "LAN". 16. "FACt rSt": Initialization menu To initialize the unit, press and hold the LOCK switch. Initialize the unit due to “FACt rSt” displayed. Press & hold LOCK Matsusada Precision PVCE/PVCEJ series...
  • Page 71: Start-Up Menu List

    : Output current scale selection ("10V" (10k) : Input voltage 0 to 10Vdc (External resistance: 0 to 10kΩ)/ "I.Con" "5V" (5k): Input voltage 0 to 5Vdc (External resistance: 0 to 5kΩ)) : Imoni scale selection ("10V": Current monitor output 0 to 10Vdc/"5V": Current monitor output 0 to 5Vdc) "Imon" Matsusada Precision PVCE/PVCEJ series...
  • Page 72: Analog Control

    In the condition, when the input power is turned on again, the unit starts in the output preparation state remained (OUTPUT indicator is flashing). Close the Remote switch to turn on the output. (Please note that the output will be turned on if the Remote switch is closed at this time.) Matsusada Precision PVCE/PVCEJ series...
  • Page 73 When "LS": Remote switch settings in the Start-up menu is set to "OFF" (disabled), it also disables 2) for floating use and 3) for reverse logic. Using the CURRENT dial switches On and OFF of the LS (Remote switch) function. Matsusada Precision PVCE/PVCEJ series...
  • Page 74: Ld (Interlock)

    When using the LD (Interlock), enable the PIN 7 on TB1 by setting "LD": (Interlock) in the Start-up menu to "On" (enabled). Use between PIN 7 and 10 on the supplied male connector for D-Sub 25-pin. Using the CURRENT dial switches On and OFF of the LD (Interlock) function. Matsusada Precision PVCE/PVCEJ series...
  • Page 75: Local Programming Mode Operation

    ・ Avoid routing the wiring for the remote control close to high-frequency power supplies. (Pay special attention when using the unit with high-voltage and floating conditions.) ・ Although the unit equips complete protection circuits, applications such as excessive voltage or energy may result in malfunction. Matsusada Precision PVCE/PVCEJ series...
  • Page 76 Set the voltage setting to Remote mode. Internal circuit External connection TTL signal (Common) 10kΩ 100Ω External relay (Common) Set the current setting to Remote mode. Internal circuit External connection TTL signal (Common) 10kΩ 100Ω External relay (Common) Matsusada Precision PVCE/PVCEJ series...
  • Page 77: Remote Mode Programming Mode

    ・ Set "E.Vol" to "Volt" and "V.Con" to "5V" in ["EXtCont": Remote Programming Settings] of the Start-up menu. (Input voltage 0 to 5Vdc corresponds to 0 to 100% of the rated output voltage.) Internal circuit External connection (Common) 0 to 5Vdc Matsusada Precision PVCE/PVCEJ series...
  • Page 78: Voltage Program Setting With External Resistance

    Set "E.Vol" to "reSi" and "V.Con" to "5k" in ["EXtCont": Remote Programming Settings] of the Start-up menu. (Resistance value 0 to 5kΩ corresponds to 0 to 100% of the rated output voltage.) Internal circuit External connection 0 to approx. (Common) 5kΩ Matsusada Precision PVCE/PVCEJ series...
  • Page 79: Current Program Setting With External Voltage (Input Voltage: 0 To 10Vdc)

    Set "E.Cur" to "Volt" and "I.Con" to "5V" in ["EXtCont": Remote Programming Settings] of the Start-up menu. (Input voltage 0 to 5Vdc corresponds to 0 to 100% of rated current output.) External connection Internal circuit (Common) 0 to 5Vdc Matsusada Precision PVCE/PVCEJ series...
  • Page 80: Current Program Setting With External Resistance

    Set "E.Cur" to "reSi" and "I.Con" to "5k" in ["EXtCont": Remote Programming Settings] of the Start-up menu. (Resistance value 0 to 5kΩ corresponds to 0 to 100% of the rated output current.) Internal circuit External connection 0 to approx. (Common) 5kΩ Matsusada Precision PVCE/PVCEJ series...
  • Page 81: Monitor And Status Output

    Note that the monitor output voltage value will be reduced by approx. 10% on the measurement equipment side if an input impedance approx. 10kΩ of it is used. Input impedance: 10kΩ → Output monitor voltage: approx. 10% reduced 100kΩ → Output monitor voltage: approx. 1% reduced Matsusada Precision PVCE/PVCEJ series...
  • Page 82: Status Output

    When using PIN 6, 11,12, 13, and 19 in floating conditions, The withstand voltage against the PIN 5 and 10 should be under 100Vdc or less. When the unit is used with a negative output especially, make sure to the above points. Matsusada Precision PVCE/PVCEJ series...
  • Page 83: Pulse And Ramp Sequence

    Setting mode. The output becomes the analog remote. Pressing the OUTPUT switch Pressing the OUTPUT switch Pulse sequence start Pulse sequence stop OFF time ON time 1 cycle The pulse sequence stops by reaching the specified counts or pressing the OUTPUT switch. Matsusada Precision PVCE/PVCEJ series...
  • Page 84: Use Cases Of Pulse Sequence

    Press & hold LOCK If the repeat count is set to “0”, the unit repeats ON and Press OUTPUT OFF of the output until pressing the OUTPUT switch. 1.0 sec 2.0 sec 1 cycle Matsusada Precision PVCE/PVCEJ series...
  • Page 85 Press & hold LOCK Press Pulse sequence stop OUTPUT 1.0 sec 2.0 sec When the repeat count is set to “2”, the unit conducts ON and OFF two times and automatically stops. 1 cycle Matsusada Precision PVCE/PVCEJ series...
  • Page 86 PROTECT Set "Cnt" (repeat count) to "2". Press LOCK By pressing and holding the LOCK switch, register the pulse sequence setting values. (* Set other time units, "m" and "h", Press & hold to "0".) LOCK Matsusada Precision PVCE/PVCEJ series...
  • Page 87 1.0V Memory “a” Memory “b” Memory “c” 1 cycle When the repeat count is set to “2”, the unit conducts ON and OFF two times and automatically stops. The unit outputs for each memory ON time. Matsusada Precision PVCE/PVCEJ series...
  • Page 88: Features Of Ramp

    ・ The ramp function cannot be used with the master/slave function together. Press Press OUTPUT LED OUTPUT OUTPUT ON ramp operation start OFF ramp operation start ON ramp time OFF ramp time Matsusada Precision PVCE/PVCEJ series...
  • Page 89: Use Cases Of Ramp

    Set the ramp function to "CVCC" (both). Press LOCK To register the ramp settings, press and hold the LOCK switch. Press & hold LOCK Press Press OUTPUT LED OUTPUT 1.0 sec OUTPUT 1.0 sec ON ramp operation OFF ramp operation Matsusada Precision PVCE/PVCEJ series...
  • Page 90 Stop when OUTPUT is OUTPUT 1.0 sec 2.0 sec 3.0 sec 4.0 sec 5.0 sec 6.0 sec 7.0 sec 8.0 sec pressed. ON ramp ON pulse OFF ramp OFF pulse operation operation operation operation 1 cycle Matsusada Precision PVCE/PVCEJ series...
  • Page 91 Set the time unit to "S" (sec). (* Set other time units, "m" and "h", to "0".) Press & hold PROTECT Set "aOn" time to 1.0sec. Press Set "bOn" time to 1.0sec. Press Set "cOn" time to 1.0sec. Press Matsusada Precision PVCE/PVCEJ series...
  • Page 92 1 cycle Memory A output ramp time Memory A output time Memory B output ramp time Memory B output time Memory C output ramp time Memory C output time Roff OFF ramp time Toff OFF time Matsusada Precision PVCE/PVCEJ series...
  • Page 93: Features Of The Master Follow-Up Function

    Set pulse sequence and ramp functions at slave units. ・ Set each output value at the master and slave units. An output signal will be sent to the slave units when the master unit turns ON/OFF its output. Matsusada Precision PVCE/PVCEJ series...
  • Page 94: Multiple Digital Interface

    ・ TCP/IP mode DHCP, Auto-IP, and Manual-IP ・ Command SCPI command and Matsusada Precision original command ・ Web interface (Refer to the interface instruction manual.) 10-2 LAN indicator LAN indicator The status can be checked when the interface is set to LAN.
  • Page 95: Interface Details

    ✽ When using units as CE marking compatible, attach ferrite cores to the cables connected to each interface for countermeasures against radiation noise. Attach the cores as close to each connector on the unit as possible. <Recommended Ferrite cores> ・ Model: GRFC-10 (Kitagawa Industries Co., Ltd.) ・ or equivalents Matsusada Precision PVCE/PVCEJ series...
  • Page 96: Lxi

    This is a DLL based on Microsoft COM (Component Object Model). It is suitable for using Visual Basic, C++, Microsoft Office VBA, and IVI-COM so on. It is also suitable for .NET language through interop assembly. Matsusada Precision PVCE/PVCEJ series...
  • Page 97: Visa Library

    By specifying the address of a measurement instrument on a Web browser, it is available to control and monitor the instrument or change its setting of the LAN communication status via the Web browser. Details are described in the interface instruction manual. Matsusada Precision PVCE/PVCEJ series...
  • Page 98: Usb (Tmc)

    "Auto-IP=ON", the setting is unavailable. ・ Default gateway ・ DNS server ・ MAC address : Read only ・ TCP/IP mode : DHCP or Auto-IP ("Manual” is automatically selected when both ”DHCP” and ”Auto-IP” are set to OFF.) Matsusada Precision PVCE/PVCEJ series...
  • Page 99: Ip Addres Setting

    VOLTAGE dial (Menu change) CURRENT CURRENT dial (Parameter change) To [A] Press & hold SET Setting changes are applied by pressing and holding the LOCK. Restarting the unit will reconnect the unit with the set value reflected. Matsusada Precision PVCE/PVCEJ series...
  • Page 100: Subnet Mask Setting

    VOLTAGE dial (Menu change) CURRENT CURRENT dial (Parameter change) To [B] Press & hold SET. Setting changes are applied by pressing and holding the LOCK. Restarting the unit will reconnect the unit with the set value reflected. Matsusada Precision PVCE/PVCEJ series...
  • Page 101: Default Gateway Setting

    VOLTAGE dial (Menu change) CURRENT CURRENT dial (Parameter change) To [C] Press & hold SET. Setting changes are applied by pressing and holding the LOCK. Restarting the unit will reconnect the unit with the set value reflected. Matsusada Precision PVCE/PVCEJ series...
  • Page 102: Dns Server Setting

    VOLTAGE dial (Menu change) CURRENT CURRENT dial (Parameter change) To [D] Press & hold SET. Setting changes are applied by pressing and holding the LOCK. Restarting the unit will reconnect the unit with the set value reflected. Matsusada Precision PVCE/PVCEJ series...
  • Page 103: How To Check Mac Address

    10 Multiple Digital Interface 10-11-5 How to Check MAC Address Return to the "LAn SEt" display. VOLTAGE VOLTAGE dial (Menu change) Return "IP" display. Press & hold SET. MAC address is read-only. Matsusada Precision PVCE/PVCEJ series...
  • Page 104: Tcp/Ip Mode Setting

    TCP/IP mode Auto-IP setting Press LOCK CURRENT CURRENT dial (Parameter change) Setting changes are applied by pressing and holding the LOCK. Restarting the unit will reconnect the unit with the set value reflected. Matsusada Precision PVCE/PVCEJ series...
  • Page 105: Ip Address Setting

    An IP address is set by DHCP and the IP is received by Auto-IP when a timeout occurs. An IP address is set by DHCP and getting the IP address is abandoned when a timeout occurs. An IP address is received by Auto-IP. An IP address is freely set by Manual. Matsusada Precision PVCE/PVCEJ series...
  • Page 106: Lan Connection Procedures 1 (Use Dhcp)

    The setting ends when the LAN indicator is lighted in green. Check the unit status if the LAN indicator is off, lighted in red, or flashing in green for one minute or more, and start over the procedure 1. Matsusada Precision PVCE/PVCEJ series...
  • Page 107: Lan Connection Procedures 2 (Use Auto-Ip)

    The setting ends when the LAN indicator is lighted in green. Check the unit status if the LAN indicator is off, lighted in red, or flashing in green for one minute or more, and start over the procedure 1. Matsusada Precision PVCE/PVCEJ series...
  • Page 108: Lan Connection Procedures 3 (Use Manual)

    Press the SET for two seconds or more to move to the Subnet mask Setting. Turn the VOLTAGE/CURRENT dials to set the subnet mask to match the network to be connected. (Refer to [10-11-2 Subnet mask Setting].) Matsusada Precision PVCE/PVCEJ series...
  • Page 109 The setting ends when the LAN indicator is lighted in green. Check the unit status if the LAN indicator is off, lighted in red, or flashing in green for one minute or more, and start over the procedure 1. Matsusada Precision PVCE/PVCEJ series...
  • Page 110: Lan Reset

    "Model name" - "Serial No." “Product name", "Serial No." Description Web password Initial value ✽ "Manual" is automatically set according to the state of the "DHCP" and "Auto-IP" settings. Pressing and holding the LOCK resets and initializes the unit. Matsusada Precision PVCE/PVCEJ series...
  • Page 111: 11 -Lis/Lrcp Options

    When using units as CE marking compatible, attach ferrite cores to the cables connected to the control connector for countermeasures against radiation noise. Attach the ferrite cores as close to the control connector as possible. <Recommended Ferrite cores> ・ Model: GRFC-10 (Kitagawa Industries Co., Ltd.) ・ or equivalents Matsusada Precision PVCE/PVCEJ series...
  • Page 112: Lis/Lrcp Options Operation

    The output can be turned off with the Interlock connected to the control connector of the "-LIs" option.。 Regarding the Interlock operation, refer to [8-2 LD (Interlock)] on page 64. ✽ GND terminals PIN 3 and 8 have the same electric potential. Matsusada Precision PVCE/PVCEJ series...
  • Page 113: Vcon Programming Control When The -Lis Option Is Installed

    ✽ GND terminals PIN 3 and 8 have the same electric potential 11-3-5 Monitor Output when the -LIs Option is Installed. The monitor output for the output voltage/current is available. ✽ GND terminals PIN 3 and 8 have the same electric potential Matsusada Precision PVCE/PVCEJ series...
  • Page 114: Vcon Programming Control When The -Lrcp Option Is Installed

    ✽ GND terminals PIN 3 and 8 have the same electric potential 11-3-8 Monitor Output when the -LRcp oiption is Installed. The monitor output for the output voltage/current is available. ✽ GND terminals PIN 3 and 8 have the same electric potential Matsusada Precision PVCE/PVCEJ series...
  • Page 115: Troubleshooting

    Is the Master or Slave setting using the Slave mode? p.41 ※ If nothing meets the above case, or if the problem is not solved after checking, please contact our sales office where you purchased the product for more information. Matsusada Precision PVCE/PVCEJ Series...
  • Page 116 Revision History Rev. No. Rev. Date Revised contents 2020/8 First edition...
  • Page 117 Warranty We will repair this product free of charge if it has malfunctioned under normal usage conditions within one year of delivery. However, repairs will be charged in the following cases, even if during the warranty period. 1. Failures or damages caused by improper handling. 2.