Sign In
Upload
Manuals
Brands
Matsusada Precision Manuals
Power Supply
R4GT Series
Matsusada Precision R4GT Series Manuals
Manuals and User Guides for Matsusada Precision R4GT Series. We have
5
Matsusada Precision R4GT Series manuals available for free PDF download: Instruction Manual, Basic Instruction Manual
Matsusada Precision R4GT Series Instruction Manual (56 pages)
Brand:
Matsusada Precision
| Category:
Power Supply
| Size: 1 MB
Table of Contents
For Safe Use of the Product
3
Table of Contents
7
Table of Contents
8
Introduction
9
Overview
9
Features
9
Lineup
9
Specifications
10
Before Use
11
Unpacking
11
Initial Inspection
11
Precautions for Handling
11
Installation
12
Installation Conditions
12
External View
13
Front Panel
13
Rear Panel
13
External Dimensions
14
Remote Interface Connector (TB1) and Function Setting Switch (SW1)
15
Remote Interface Connector (TB1)
15
Function Setting Switch (SW1)
16
Basic Operation to Output
17
Normal Operation
18
Operating Mode Description
18
Constant Voltage (CV) Mode
18
Constant Current (CC) Mode
18
Crossover Mode
18
Output ON/OFF
19
Presetting the Output Voltage and Output Current
19
OVP (Overvoltage Protection) and OCP (Overcurrent Protection)
19
FINE Switch
21
Lock
22
Power Failure Protection
23
Last Setting Memory
23
LS (Remote Switch) ON/OFF
24
LD (Interlock)
26
Remote Sensing
27
Error List
27
Basic Operation
28
Single Operation
28
Series Operation
28
Parallel Operation
29
Useful Features
30
Master/Slave Setting (with the -Lgmb Option)
30
Description of Master/Slave Function
30
Master/Slave Connection
31
Multi-Set Function
32
Startup Menu
34
Setting the Startup Menu
34
Each Menu Mode
36
Startup Menu List
40
Delay Trigger Function
41
Using the Delay Trigger Function
41
Stopping the Delay Trigger in an Emergency
41
Using the Delay Trigger Function in Master/Slave Configuration (with -Lgmb Option)
41
Analog Control
44
Local Programming Mode Operation
44
Switching Local/Remote Mode (Voltage/Current Mode Setting)
44
Remote Programming
45
Voltage Program Setting with External Voltage
46
Voltage Program Setting with External Resistance
46
Current Program Setting with External Voltage
47
Current Program Setting with External Resistance
47
Monitor and Status Outputs
48
Monitor Output
48
Status Output
48
Parallel Operation
50
Introduction of Pressure Welding Connector Tools
52
Troubleshooting
53
Advertisement
Matsusada Precision R4GT Series Instruction Manual (60 pages)
Brand:
Matsusada Precision
| Category:
Power Supply
| Size: 1 MB
Table of Contents
Table of Contents
3
Introduction
5
Greetings
5
Precautions for Handling
5
External Appearance
6
Lgmb Option
6
Lgob Option
6
Lus1 Option
7
Lrs Option (for R4G Series)
7
Connection
8
Connect AC Input Cable
8
Connecting CO-G32/CO-G32M/Co-E32/CO-E32M/Co-U32M
8
Connecting CO-OPT2-9/CO-OPT2-25/CO-OPT4-25
9
Connecting Interface
10
Connecting -Lgmb Option to CO-MET2-9/CO-MET2-25/CO-MET4-25
10
Connecting -Lgmb Option to CO-G32M
11
Connecting -Lgmb Option to CO-U32M
12
Connecting -Lgmb Option to CO-E32M
13
Connecting -Lgob Option to CO-OPT2-9/CO-OPT2-25/CO-OPT4-25
14
Connecting -Lgob Option to CO-G32
15
Connecting -Lgob Option to USB-OPT
16
Connecting -Lgob Option to CO-E32
17
Connecting -Lus1 Option
18
Connecting -Lrs Option (for R4G Series)
18
Digital Control and Interface
19
Outline
19
Setting GPIB Address and Delimiter
19
USB Setting
19
LAN Setting
19
Cross/Straight Changeover Switch(-Lrs Option: R4G Series)
19
Upper Connection
20
CO-M Cable Connector Interface (-Lgmb Option)
21
CO-MET2-9/CO-MET2-25 Interface (-Lgmb Option)
22
CO-OPT2-9/CO-OPT2-25 Interface (-Lgob Option)
23
CO-MET4-25/CO-OPT4-25 (-Lgmb Option or -Lgob Option)
24
RS-232C Cable Connector Interface (-Lrs Option: R4G Series)
25
Digital Program
26
Summary of Syntax
26
Multiple Command
27
Character Set for the Command
27
Returned Data
27
Checking Digital Operation
28
Checking Digital Operation (-Lgmb Option with CO-MET2-9/CO-MET2-25/CO-MET4-25)
28
Lgmb Option with CO-G32M
29
Lgmb Option with CO-U32M
30
Lgmb Option with CO-E32M
31
Lgob Option with CO-OPT2-9/CO-OPT2-25/CO-OPT4-25
32
Lgob Option with CO-G32
33
Lgob Option with USB-OPT
34
Lgob Option with CO-E32
35
Lus1 Option
36
Lrs Option
37
Command
38
Command List
38
Reference
40
Minimum Setting / Return Value for Commands
55
Matsusada Precision R4GT Series Instruction Manual (44 pages)
Brand:
Matsusada Precision
| Category:
Power Supply
| Size: 1 MB
Table of Contents
Table of Contents
3
Outline
5
CC-Link
6
Specification of the CC-Link
6
Installation of the CC-Link and Construction the Network
6
CSP+ File
7
Setting the CC-Link
7
Indicator
7
How to Set the CC-Link Operation
8
How to Set the CC-Link Mode for R4G/R4GT
8
Set the Mode to the CC-Link Mode
8
Setting the Station Number
9
Setting the Baudrate
10
Applying the Settings
10
Confirming Start-Up of the CC-Link for R4G/R4GT
11
Communicating with the Master
11
Controlling with the CC-Link [Usage Example]
12
Starting up R4G/R4GT
12
Completing the Initial Setting
13
Setting the Voltage / Current
14
Turning the Output on
16
Confirming the Monitor Value
17
Communication Data
19
Outline of the Communication Data (Slave → Master)
19
RX Bit Data (Slave → Master)
23
Rwr Word Data (Slave → Master)
26
Outline of the Communication Data (Master → Slave)
28
RY Bit Data (Master → Slave)
31
Rww Word Data (Master → Slave)
33
R4G/R4GT Model Correspondence Table
40
Troubleshooting
41
Inquiries
41
Advertisement
Matsusada Precision R4GT Series Instruction Manual (44 pages)
Brand:
Matsusada Precision
| Category:
Portable Generator
| Size: 0 MB
Table of Contents
Table of Contents
8
Introduction
9
Greetings
9
Overview
9
Precautions for Handling
9
Start-Up Menu (Lde Option Only)
10
Start-Up Menu
10
Start-Up Menu Setting
10
Each Menu Mode
10
Using Lde Option
16
Features of Pulse Sequence Function
16
Example of Using Pulse Sequence Function
17
Features of Ramp Function
21
Example of Using Ramp Function
22
Using for Particular Purpose
26
Connection
26
Example of Operation
26
Lic Option
27
SET Switch
27
SET Display
27
Present Current Integration Value/Time Display
28
Previous Current Integration Value Display
28
Cumulative Current Integration Value Display
29
OVP/OCP Switch
30
Stop Setting by Time
30
Stop Setting by Current Integration Value
31
Current Integration Value Display Unit Setting
31
Using with Digital Control
32
Multi-Command
32
Command
32
Command List
32
Command Description
34
Matsusada Precision R4GT Series Basic Instruction Manual (8 pages)
Brand:
Matsusada Precision
| Category:
Portable Generator
| Size: 0 MB
Advertisement
Related Products
Matsusada Precision R4G Series
Matsusada Precision R4G6-2
Matsusada Precision R4G8-5
Matsusada Precision R4G18-3
Matsusada Precision R4G18-5
Matsusada Precision R4G3-3
Matsusada Precision R4G120-0.3
Matsusada Precision R4G120-0.6
Matsusada Precision R4G18-10
Matsusada Precision R4G36-5
Matsusada Precision Categories
Power Supply
Portable Generator
Amplifier
Recording Equipment
Racks & Stands
More Matsusada Precision Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL