Download Print this page

Borg & Overstrom E4 Install & Operation Manual

Hide thumbs Also See for E4:

Advertisement

Quick Links

Release date 01.07.2022
E4 Install & Operation
Manual
Safety
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
The unit should be isolated from the electricity supply before removal of any covers. Great care must be employed when
working with high pressure carbon dioxide, and in no cases should the maximum operating pressure of 0.4MPa (4 bar)
be exceeded.
The appliance is not suitable for installation in an area where a water jet could be used.
The appliance has to be placed in a horizontal position.
WARNING: Keep ventilation openings in the appliance enclosure or in the built-in structure clear of obstruction.
WARNING: When positioning the appliance, ensure the supply cord is not trapped or damaged.
WARNING: Do not locate multiple portable socket-outlets or portable power supplies at the rear of the appliance.
This appliance is intended to be used in household and similar applications such as:-
Staff kitchen areas in shops, offices and other working environments
Farm houses and by clients in hotels, motels and other residential type environments
Bed and breakfast type environments
Catering and similar non-retail applications
A-weighted emission sound pressure level is below 70 dB(A)
R290 is a refrigerant-grade propane used on a wide range of commercial refrigeration and air
conditioning units. A highly pure propane, it has a low environmental impact and nominal global
warming potential (GWP), meaning it possesses no qualities that can destroy the ozone layer. R290
also is the preferred hydrocarbon alternative of the Environmental Protection Agency (EPA),
substituting more harmful fluorocarbon refrigerants like R22, R134a, R404a and R502.
Units with R290 can only be maintained and repaired by authorized technicians who are
properly trained and certified.
We're online. Chat with us now!

Advertisement

loading
Need help?

Need help?

Do you have a question about the E4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Borg & Overstrom E4

  • Page 1 Release date 01.07.2022 E4 Install & Operation Manual Safety This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 2 R600a is a refrigerant-grade propane used on a wide range of commercial refrigeration and air conditioning units. A highly pure propane, it has a low environmental impact and nominal global warming potential (GWP), meaning it possesses no qualities that can destroy the ozone layer. R600a also is the preferred hydrocarbon alternative of the Environmental Protection Agency (EPA), substituting more harmful fluorocarbon refrigerants like R22, R134a, R404a and R502.
  • Page 3 The WEEE symbol indicates that this item contains electronic components which must be collected and disposed of separately. Never dispose of electrical waste in general municipal waste. Collect and dispose of such waste separately. Make use of the return and collection systems available to you, or your local recycling programme.
  • Page 4 Specification E4 - 230v...
  • Page 5 COOLING SYSTEM Stainless steel direct chill coil encased in a solid-block system for instant response cool down action. Ultra efficiency compression system with capillary control. Environmentally friendly R290 refrigerant. COLD TEMPERATURE 2°C - 11°C CHILLED & SPARKLING CAPACITY 50L/h HOT TEMPERATURE 92°C HOT CAPACITY 15L/h...
  • Page 6 MINIMUM TO MAXIMUM INLET WATER 0.05MPa (0.5 bar) - 1.0 MPa (10 bar) PRESSURE Internally regulated to 0.2 MPa (2 bar) CO2 PRESSURE 0.4MPa (4 Bar) Maximum MINIMUM TO MAXIMUM AMBIENT 5°C - 35°C ROOM OPERATING TEMPERATURE CLIMATIC CLASS E4 - 115v...
  • Page 7 COOLING SYSTEM Stainless steel direct chill coil encased in a solid-block system for instant response cool down action. Ultra efficiency compression system with capillary control. Environmentally friendly R600a refrigerant. COLD TEMPERATURE 37°F CHILLED & SPARKLING CAPACITY 13.2 Gal/h HOT TEMPERATURE 198°F HOT CAPACITY 4 Gal/h...
  • Page 8 RATED CURRENT - CHILLED, SPARKLING & 8.3A FUSE RATING MINIMUM TO MAXIMUM INLET WATER 0.05MPa (0.5 bar) - PRESSURE 0.3 MPa (3 bar) CO2 PRESSURE 0.4MPa (4 Bar) Maximum MINIMUM TO MAXIMUM AMBIENT 41°F - 95°F ROOM OPERATING TEMPERATURE CLIMATIC CLASS...
  • Page 9 Model Overview Introduction Hygienic and ergonomic, E4 flourishes in all environments – from boardroom to sports hall. Its compact size, large dispense area for bottles, multiple water options and flexible configuration. The E4 features a flush control panel with no intricate buttons to harbour germs and contaminants, the touch sensitive...
  • Page 10 Component/Feature Overview E4 - Major Components Contents: 1 no Warranty Card 1 no E4 Unit 1 no 2.0m Power Cord Set...
  • Page 11 1. Unit Lid, 2. Side Panel, 3. Carry Handle, 4. Control Panel, 5. Dispense Outlet, 6. Drip Tray, 7. Power Connection, 8. On/Off Switch, 9. CO2 Inlet*, 10. Water Inlet, 11. Hot Tank Switch...
  • Page 12 Please Note: Mains Installation Kit & Filters are supplied as extra items according to individual ordering requirement. *Sparkling versions only Dimensions...
  • Page 13: Installation Requirements

    Installation Installation Requirements Identify a suitable location for the E4 unit. It should be positioned within 2.0m of suitable services connections. Allow 15cm of free space at the rear for ventilation. The E4 unit must be installed in accordance with the relevant requirements of: The appropriate building regulations by application of either The Building Regulations (England and Wales), The Building Regulations (Scotland) or The Building Regulations (Northern Ireland).
  • Page 14: Operation

    Operation Tap Control Panel 1. Unlock Button (commissioning mode), 2. Chilled Dispense, 3. Sparkling Dispense, 4. Hot Dispense, 5. Warning Symbol. Note: CSH Version shown Basic Functions...
  • Page 15: Warning Symbol

    Connectivity Bluetooth hands free app dispense Bluetooth alarmed waste kit enabled Foot switch operation enabled E4 Installation & Water Connection Connect to the water supply. Connect the CO2 supply from gas Connect the chiller to the electricity regulator, ensuring the pressure is set to supply and ensure unit is switched on.
  • Page 16 Turn on the water supply. The carbonator should be purged of The hot versions will have a label air by activating the sparkling water covering the hot switch on the dispense for approximately 10 backplate. Press the unlock icon then seconds.
  • Page 17 Unpack CO2 Regulator and fit elbow Attach the regulator to the disposable Connect the assembled CO2 bottle fitting to spigot outlet. CO2 bottle, ensuring the small and regulator to the CO2 inlet using a pressure relief vent in the stem is facing ¼”...
  • Page 18 NOTE: Sparkling water flow rate factory setting = 2.4L per minute MAX. This may need adjusting depending on inlet pressure. To do so follow below steps: Remove the 2 screws Remove the right hand side Locate the flow control Flow can then be adjusted holding the unit lid down panel screws.
  • Page 19 Maintenance & Cleaning Sanitisation Guide NOTE: Failure to use sanitising products and processes approved by Borg & Overström will invalidate your warranty. This operation must only A sanitisation procedure is Turn off incoming mains Briefly press chilled be carried out by trained recommended every 6 water dispense button to release...
  • Page 20 Remember to include the Attend to any cosmetic Reconnect the power and When the external drip tray. If a Waste marks as needed. For this switch on the dispenser. cleaning (minimum 5 Overflow System is fitted, we recommend the use of minutes) is completed, flush empty this and flush Bioguard External...
  • Page 21 Press and hold the Sparkling Turn off the water supply. The tank is empty of Ensure to release the water dispense button until sparkling water when only Sparkling water button and all the water is expelled and CO2 is being released. take care to avoid releasing only CO2 gas is being excess amounts of CO2 gas...
  • Page 22 Advanced Troubleshooting Fault Diagnostics...
  • Page 23 Problem/Report Possible Cause Suggested Action No Water Dispensing Power supply turned off Check the power supply has been fitted properly and turned on. Water Pressure Check water flow through the regulator. Regulator Replace if necessary. Check Tap HMI Control Check fault codes. Water isolated from Check water inlet supply.
  • Page 24: Fault Codes

    Problem/Report Possible Cause Suggested Action Water lying on top edge of Overflowing drip tray or Empty waste container and check drainpipe is not lower door panel and/or waste container blocked. bottom of cabinet Water lying in bottom of Leak in pipe work Contact your distributor.
  • Page 25 Technical Information Chilled & Ambient Circuit Schematic Chilled, Ambient & Sparkling Circuit Schematic...
  • Page 26 Chilled, Ambient & Hot Circuit Schematic...
  • Page 27 Chilled, Sparkling & Hot Circuit Schematic...
  • Page 28 Water Pathway - Chilled & Ambient...
  • Page 31 Water Pathway - Chilled, Ambient & Sparkling...
  • Page 34 Water Pathway - Chilled, Ambient & Hot...
  • Page 36 Water Pathway - Chilled, Sparkling & Hot...
  • Page 39 Spares E4 Exploded Parts Diagram...
  • Page 40: Spares List

    Spares List...
  • Page 41 Part No. Description 702546 Main Control PCBA • • • • 701630 Top Panel • • • • 701678 Side Panel • • • • 720341 Front Panel Black • • • • 720383 Front Panel Silver • • • •...
  • Page 42 Part No. Description 462855 8mm Bulkhead Connector • • • • 701886 8mm PRV 2 Bar • • • • 701729 Hot Inlet Solenoid • • 701937 8mm 2 Way Solenoid • • • 701992 8mm 3 Way Solenoid • 462859 8mm Stem Elbow •...