Siemens SITRANS FX330 Operating Instructions Manual page 78

Vortex flowmeters
Table of Contents

Advertisement

OPERATION
6
Function
.7.1 Current Out. Meas.
.7.2 0% Range
.7.3 100% Range
.7.4 Error Function
.7.5 Low Error Current
.7.6 High Error Current
.8 Binary Output
.9 Pulse Output
.10 Frequency Output
.11 Status Output
.12 Limit Switch
.13 Flow Totalizer
.14 Energy Totalizer
.15 1. Meas. Page
.16 2. Meas. Page
Table 6-25: A11.4 Application Assistant - Heat Measurement
A11.5 Application Assistant - Gas
Function
.1
.2 Units
.2.1 Volume Flow
.2.2 Norm. Vol. Flow
.2.3 Mass Flow
.2.4 Volume
.2.5 Norm. Volume
.2.6 Mass
.2.7 Temperature
.2.8 Pressure
.2.9 Density
.3 Process
.3.1 Fluid
.3.2 Medium
.3.3 Time Constant
.3.4 Low Flow Cutoff
.4 Current Input
.5.1 Temp. Source1
.5.2 Temp. Source2
.6 Gas Mixture
78
Setting / Description
Select "Gross Power" or "Net Power".
The set value represents 4 mA at the current output. Usually 0% flow = 4 mA, but it is
also possible to define a higher flow value for 4 mA.
The set value represents 20 mA at the current output. Usually 100% flow = 20 mA, but it
is also possible to define a lower flow value for 20 mA.
Same options as in A11.1.5.4.
3.5...3.6 mA
21...21.5 mA
Same options as in A11.1.6.
Same options as in A11.1.7.
Same options as in A11.1.8.
Same options as in A11.1.9.
Same options as in A11.1.10.
Same options as in A11.1.11.
Same options as in A11.1.12.
Same options as in A11.1.13.
Same options as in A11.1.14.
Setting / Description
Same options as in A11.1.2.
Select unit (default: according to order specification or m
Select unit (default: according to order specification or Nm
Select unit (default: according to order specification or kg/h).
Select unit (default: according to order specification or m
Select unit (default: according to order specification or Nm
Select unit (default: according to order specification or kg).
Select unit (default: according to order specification or °C).
Select unit (default: according to order specification or bar).
Select unit (default: according to order specification or kg/m
Select: "Gas", "Wet Gas" or "Gas Mixture".
If fluid is "Gas" or "Wet Gas" (for details refer to Gas options for gas measurement on
page 63).
0...100 s
Enter low flow cutoff point in current volume flow unit.
Same options as in A11.3.4.
Internal / External / External HART / Not Available
Internal / External / External HART / Not Available
Temperature source 1 and 2 must be different.
If fluid = "Gas Mixture", enter gas mixture in %.
www.siemens.com/flow
SITRANS FX330
3
/h).
3
/h).
3
).
3
).
3
).
08/2022 - A5E36751269-AG EN

Advertisement

Table of Contents
loading

Table of Contents