Dimplex Optimyst OLF46-AM Manual page 15

Hide thumbs Also See for Optimyst OLF46-AM:
Table of Contents

Advertisement

Installation
240 V Hardwire Installation
You will need a 4-wire 240 V supply (L1, L2, Neutral, and Ground).
1. Connect the black L1 wire from the unit to the L1 wire from the power supply with a wire connector.
2. Connect the red L2 wire from the unit to the L2 wire from the power supply with a wire connector.
3. Connect the white N wire from the unit to the neutral wire from the power supply.
4. Connect the green G wire from the unit to the ground wire from the power supply with a wire connector or attach the
grounding wire.
5. Ensure all wire connections are tight.
Optional Plug Kit (OLFPLUG, sold separately)
WARNING: Power cord option is only suitable for 120 V installations.
1. Remove the 3 screws that hold the connector plate.
2. Connect the black L1 wire from the unit to the black wire of the plug kit.
3. Connect the white N wire from the replace to the white wire from the plug kit.
4. Connect green G wire from the replace to the green wire from the plug kit.
5. Ensure all wire connections are tight.
6. Secure the power cord's pre-installed cover plate using the screws removed when removing the connector plate. The
previously removed connector plate can be disposed of.
WARNING: This heater is not intended for use with an extension cord. Plug the cord directly into an appropriate
wall receptacle.
White - Neutral
Black - L1
Red - L2
Green - Ground
Figure 11
White - Neutral
Black - L1
Red - L2
Green - Ground
Figure 12
White - Neutral
120 V
Black - L
POWER
SUPPLY
(BREAKER
PANEL)
Green - Ground
White - Neutral
240 V
POWER
Black - L
SUPPLY
(BREAKER
RED – L2
PANEL)
Green - Ground
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optimyst olf66-amOptimyst olf86-am

Table of Contents