Dimplex Optimyst OLF46-AM Manual

Dimplex Optimyst OLF46-AM Manual

Hide thumbs Also See for Optimyst OLF46-AM:

Advertisement

Quick Links

Installation and User's Guide
We value your feedback!
Your input helps to create even better
products and experiences.
Share the warmth and leave a review.
dimplex.com/sharethewarmth
IMPORTANT SAFETY INFORMATION:
Read this manual first before attempting to install or use this electric fireplace. Always comply with the
warnings and safety instructions contained in this manual to prevent personal injury or property damage.
To view the full line of Dimplex products, visit www.dimplex.com
7216400100R04
Models
OLF46-AM
OLF66-AM
OLF86-AM

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex Optimyst OLF46-AM

  • Page 1 Read this manual first before attempting to install or use this electric fireplace. Always comply with the warnings and safety instructions contained in this manual to prevent personal injury or property damage. To view the full line of Dimplex products, visit www.dimplex.com 7216400100R04...
  • Page 2: Table Of Contents

    Warranty ..............28 www.dimplex.com...
  • Page 3: Welcome

    Welcome Thank you and congratulations for choosing to purchase a Dimplex replace. Please carefully read and save these instructions. WARNING: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, re hazard and will void the warranty.
  • Page 4: Important Instructions

    ⑱ Regular cleaning and maintenance is required to contact Glen Dimplex Americas Technical ensure safe and correct operation. Service at 1-888-346-7539. ! NOTE: Changes or modifications not ⑦...
  • Page 5 IMPORTANT INSTRUCTIONS FCC Compliance WARNING: This product can expose you to chemicals including nickel which is known to CAUTION: This unit has been tested and found the State of California to cause cancer. For more to comply with the limits for Class B digital information, visit www.P65Warnings.ca.gov device, pursuant to part 15 of the FCC Rules.
  • Page 6: Technical Specifications

    " 441 mm 31 ½" 800 mm 8 ½" 217 mm 11" 280 mm Model OLF46-AM 47 ½" 1206 mm 1170 mm " OLF66-AM 67 ½" 1714 mm 1678 mm " OLF86-AM 87 ½" 2222 mm 2186 mm " www.dimplex.com...
  • Page 7: Package Contents

    Package Contents Quantity Image Description OLF46-AM OLF66-AM OLF86-AM Firebox Front Glass Bag of Small Acrylic Crystals Bag of Large Acrylic Crystals Bag of Extra-Large Acrylic Crystals Driftwood Spare Transducer Keep it in a secure location for future use. Suction Cup Do not dispose of the suction cup after installation.
  • Page 8 1 ½" Wood Screws *Package contents are subject to change Optional Accessories Model Number Description OLF46-AM OLF66-AM OLF88-AM Quantity Air Intake Grille X-00275 X-00275 X-00275 Accessory Air Intake Grille for fresh air inlets. *Please contact your local Dimplex dealer for inquiries. www.dimplex.com...
  • Page 9: Installation

    Installation Placement Figure 2 NOTE: For optimized viewing angle of the ame, it is recommended that the bottom of the unit be mounted between 5" (13 cm) and 50" (127 cm) from the ground. (Figure 2) Installation in a Bathroom If this unit is installed in a bathroom, it must be protected by a GFCI receptacle or circuit.
  • Page 10: Preparing The Firebox For Installation

    Electrical Installation section (page 14). 3. For permanent heat disable only: follow the instructions for disconnecting the heat function in the section Heater Hardware Disconnect (page 16). www.dimplex.com...
  • Page 11: Framing

    Installation Framing 1. Prepare a wall with a framed opening, following the dimensions in the table below. Openings beneath the unit are required in order to allow for air ow to reach the underside of the unit. (Figure 6) Framing Dimensions Drywall Opening Width Depth...
  • Page 12: Installation Instructions

    10. Finish the installation using the nishing materials of your choice. 11. Place the media as desired and install the front glass. 12. Press the standby button on the remote to initialize the remote. www.dimplex.com...
  • Page 13: Water Supply Connection

    Plumbing Instructions The units are designed to be hard plumbed by connecting to a water source using standard ¼" (6.4 mm) O.D. tubing. A plumbing accessory kit CDFIPLUMB-KIT, designed for use with copper piping, is available from your Dimplex dealer.
  • Page 14: Electrical Installation

    Red - L2 (BREAKER PANEL) Green - Ground Green - Ground White - Neutral White - Neutral 240 V Black - L1 POWER Black - L SUPPLY (BREAKER Red - L2 RED – L2 PANEL) Green - Ground Green - Ground www.dimplex.com...
  • Page 15 Installation 240 V Hardwire Installation White - Neutral White - Neutral You will need a 4-wire 240 V supply (L1, L2, Neutral, and Ground). 120 V Black - L1 Black - L POWER 1. Connect the black L1 wire from the unit to the L1 wire from the power supply with a wire connector. SUPPLY 2.
  • Page 16: Heater Hardware Disconnect

    3. Locate the main control board. The heater hardware disconnect jumper location is labeled “J2”. (Figure 13) 4. Remove the heater hardware disconnect jumper. 5. Secure the upper panel back in its original position. 6. Reconnect the wire for the upper LED lights, and secure in place. Figure 13 Heater Hardware Disconnect Jumper www.dimplex.com...
  • Page 17: Flame Baf Es

    Installation Flame Baffles The unit comes with breakable and slotted baf es to Flame Output Slot create a customized ame. The unit can be operated with Figure 14 or without the baf es. The baf es will create spacing to customize a unique ame appearance.
  • Page 18: Front Glass Installation

    5. Remove the suction cups and clean any ngerprints or debris off the glass with a nonabrasive glass cleaner. NOTE: Do not dispose of the suction cups! Keep them in a secure location, as they may be needed for maintenance and service on this replace. www.dimplex.com...
  • Page 19: Operation

    The replace is capable of being controlled using the Flame Connect app for mobile devices. For up-to-date information about the app, please visit www.dimplex.com/fcapp. NOTE: The replace will not operate using the provided remote control when the app is open on a paired mobile device.
  • Page 20 Press repeatedly to cycle the top light brightness settings: B1 - Brightness level 1 B2 - Brightness level 2 Brightness B3 - Brightness level 3 B4 - Brightness level 4 B5 - Brightness level 5 B6 - Pulsating effect www.dimplex.com...
  • Page 21: Resetting The Temperature Cutoff Switch

    Operation Additonal Functions to be Performed from the Remote Control Press repeatedly to set the duration of the timer. The replace goes into standby after the time has elapsed. The timer can be set from 30 minutes (display shows 0.5Hr) to 8 hours in intervals of 30 minutes.
  • Page 22: Factory Reset

    3 seconds. “FILLING” will scroll across the display for the duration of the priming. Once the lling is complete, the display will show “FULL”, the icon will disappear, and 4 beeps will follow. The unit will return in standby mode. 5. To start the unit press once. The warm up sequence will start. www.dimplex.com...
  • Page 23: Maintenance

    This unit comes with replacement transducers. Additional transducers may be purchased at www.dimplex.com/replacement_parts (9601210100RP). ! NOTE: To remove the transducer, release the retaining tab in the sump and remove transducer.
  • Page 24: Troubleshooting

    Troubleshooting For more troubleshooting, consult the OLF Service Manual which can be found at www.dimplex.com/customer_support/technical_and_troubleshooting Problem Display Cause Solution There is a brief delay after Normal operation pressing Fireplace does not turn on with Ensure the power switch is on.
  • Page 25 Troubleshooting Problem Display Cause Solution Press and hold at the same time on the hidden touch Heater is disabled. CD52 controls for 3 seconds to disable or enable the heat function. If installation with heat is desired, Heater has been permanently reinstall jumper wire on main CD43 board if available or purchase new...
  • Page 26: Wiring Diagrams

    Wiring Diagrams OLF46-AM WARMUP HEATER OLF66-AM WARMUP HEATER www.dimplex.com...
  • Page 27 Wiring Diagrams OLF86-AM WARMUP HEATER...
  • Page 28: Warranty

    Warranty • Glen Dimplex Americas will in its sole discretion either OPTI-MYST LINEAR™ 2-YEAR LIMITED WARRANTY repair or replace such defective product or part without Section 1 Products to which this Limited Warranty charge. If Glen Dimplex Americas is unable to repair or...
  • Page 29 For more information on the Flame Connect app, visit dimplex.com/fcapp 1-888-346-7539 | www.dimplex.com In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice. A BRAND OF GLEN DIMPLEX AMERICAS © 2023 Glen Dimplex Americas...

This manual is also suitable for:

Optimyst olf66-amOptimyst olf86-am