Preparing The Firebox For Installation; Fresh Air Inlets - Dimplex Optimyst OLF46-AM Manual

Hide thumbs Also See for Optimyst OLF46-AM:
Table of Contents

Advertisement

Installation

Fresh Air Inlets

CAUTION: Failure to include a fresh air inlet will result in poor ame performance and damage to the replace.
A fresh air inlet is required. The air inlet must allow for the air path to reach the underside of the unit. This will have to
be accounted for in the framing and drywall installation. See the table below for air inlet requirements for each model.
See Figure 3 for examples on incorporating fresh air inlets in the installation.
If the air inlet is concealed using a grille, the covered area must be compensated for by having a larger opening.
Model
OLF46-AM
OLF66-AM
OLF86-AM
Figure 3
Recessed Inlet

Preparing the Firebox for Installation

1. The unit is provided with mounting brackets attached
(Figure 4). Remove the mounting brackets before
installation. They will need to be reinstalled during
installation once the rebox is placed into the framing.
2. If using the plug accessory kit (OLFPLUG, sold
separately), wire it following the instructions for the
plug kit in the Electrical Installation section (page 14).
3. For permanent heat disable only: follow the
instructions for disconnecting the heat function in the
section Heater Hardware Disconnect (page 16).
10
Air inlet area required
80 in
516 cm
120 in
774 cm
160 in
1032 cm
Front Register
Figure 4
Side Registers
*For best results in this
con guration include an opening
on each side of the replace
www.dimplex.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Optimyst OLF46-AM and is the answer not in the manual?

This manual is also suitable for:

Optimyst olf66-amOptimyst olf86-am

Table of Contents