Unauthorised modifica�ons by the user also mean possible damage to the device, for which NCTE cannot be held liable. NCTE reserves the right to make changes to the product without prior no�ce.
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D Table of Contents NCTE-Readout Unit Manual ..........................1 1. Safety instruc�ons and assembly recommendations ..................3 1.1. Safety instructions ..........................3 1.2.
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 1. Safety instruc�ons and assembly recommenda�ons 1.1. Safety instructions ● Please read the instructions carefully before first use. ●...
2.2. Properties ● Power supply 15 ... 30 VDC ● compa�ble to all NCTE torque sensors with analog signal, 0 ... 10V - input ● counter input for incremental protractors or signal types UP-DOWN/STEP DIRECTION ● Recording possibility of min./max. measured values ●...
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 2.3. Overview / descrip�on – front side of the device Func�on Description LEFT/ESC Pushbuttons for menu control to confirm or undo selected se�ngs.
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 2.4.1. Supply voltage The readout unit is to be operated with constant voltage of 15...30 VDC. ATTENTION! Reversing the polarity or exceeding the maximum specified voltage will damage the readout unit.
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 2.4.4. IN1/IN2 digital inputs The readout unit is equipped with two external inputs, which can be used to acquire or stop measurements depending on the opera�ng status.
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 3. Display / LCD display In the main menu of the readout unit, various information on different se�ngs is displayed. Switching between the modes is done with the keys .
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 4. Menu To enter the menu, press the key. To select the individual menus, press the key, to select further...
Page 10
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D Source Torque input / angle measurement input / 0-10 V input Limit value range /ON -9999.999…+9999.999 Limit value range /OFF -9999.999…+9999.999...
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 4.1. Se�ngs – Counter input Se�ngs of parameters for counter input (A and B signals). Counter reset Reset�ng the acquired coun�ng pulses of the input counter...
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 4.2. Se�ng - 0…10 V voltage input Se�ngs of the parameters for the voltage input. Input set�ng Removal of the voltage input (offset) Func�on end...
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 4.4. Se�ngs – PK outputs / relay outputs Enables on/off switching of PK1/PK2 relays. PK1/PK2 relays can be switched on and off after exceeding values and in case of overload by fixed values, which can be torque sensors, angle measurements and input voltage.
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 4.5. Measurement data acquisition Enables se�ngs on the readout unit for recorded measurement data and the recorded minimum/maximum values.
Page 15
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D Acquisi�on time (times for measurement data) Se�ng of the acquisi�on time with which the data are recorded as well as the current maximum value of the torque input.
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D Regardless of the selected acquisi�on mode, values of 3 measurement inputs (input torque, input angle and input voltage value) are always recorded.
Page 17
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D Display se�ng Basic se�ngs after switching on the device Func�on end Possibility to select se�ngs Change confirmation and menu end Password se�ng...
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 4.7. Memory card Memory card information Informa�on about memory size in MB (megabyte) and available memory capacity Return to menu...
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 5. Memory card The readout unit can record acquired measurement data on a memory card located on the back of the device.
NCTE-Readout Unit Manual T E S T E N G I N E E R I N G L T D 7. PC Program The readout unit can cooperate with the PC program, which allows se�ngs at PC level. Furthermore, the program allows to collect measurement data in real time and save them as a file (*.csv →...
Do not use products such as water or oil to clean the unit. - All data without guarantee subject to technical changes - Hydrotechnik UK Test Engineering Ltd, 1 Central Park, Lenton Lane, Nottingham, NG7 2NR, UK +44 (0)115 9003 550 sales@hydrotechnik.co.uk...
Need help?
Do you have a question about the NCTE and is the answer not in the manual?
Questions and answers