Safety Precautions - golmar ART W LITE/G2+ Quick Manual

Hide thumbs Also See for ART W LITE/G2+:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
ART W LITE/G2+
4
MONITOR

SAFETY PRECAUTIONS

Always disconnect the power supply
-
before installing or making modifications to the device.
.
- The fitting and handling of these devices must be carried out by
.
- The wiring must run at least 40 cm. away from any other wiring.
- Do not overtighten the screws on the connector.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors.
- Always follow the instructions contained in this manual.
( )
CHARACTERISTICS
*
- Hands-free monitor.
- 4,3
" TFT c
olo r
u screen
.
- Monitor with Wifi transmission for call forwarding to a smartphone (no additional power supply
needed for WI-FI functionality).
.
-
Function push buttons
for access and selection of menu function.
- Monitor
with simple installation (non-polarised 2 wires bus)
-
User menu
.
.
-
Installer menu
.
.
-
Image and communication settings menu
.
.
-
Output auxiliary call repeater (max.
50mA/12V ).
.
- "HZ" input for calls from apartment front door.
.
- Push buttons for door release 1 and 2.
.
-
Notification l
eds.
.
-
Configuration switches to assign the
call
address
- Function codes to define whether the monitor is master or slave (default: master).
( )
SYSTEM OPERATION
*
- To make a call, the visitor must press the button of the apartment; an audible sound indicates that the
call is being made and
door panel
LED
progress' message appears indicating that a call is being made. At this moment, the apartment's
monitors receive the call. If another apartment is called by mistake, press the button for the correct
apartment and the first call will be cancelled.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it
exists) without the visitor knowing and icon
image from slave monitors 2 or 3, press
one of the buttons of the monitor to display the image
call is not answered within 45 seconds,
door panel
- To establish communication, press
the button below
displayed on the screen in red colour, door panel LED
- Co
mmunication
will last for 90 seconds or until
screen is
pressed. When communication ends,
become free. If vocal synthesis is enabled, a 'Communication is finished' message will indicate that
the call is over.
-
To open door
or
of the door panel
, press the
2
1
the screen
during the call or communication processes: one press will activate the lock release for
seconds and
door panel
LED
will also turn on for seconds. If vocal synthesis is enabled, a 'Door
is open' message will be indicated on the door panel.
-
Detailed operation
and configuration
of the monitor
( )
INSTAL A
L TION OF THE
MONITOR
*
( )
*
For more information, see "TART 4
W LITE
https://doc.golmar.es/search/manual/50122639
authorised personnel
.
.
dc
(1 to 128)
and
end of line.
will turn on. If vocal synthesis is enabled, a 'Call is in
displayed on the screen
in
green
colour
. To view the
LED
will turn off and the system will become free.
icon
sh wn on
o
the screen. The icon
will turn off and the led
will turn on.
the button below
on-the-hook icon
shown on the
door panel
LED
will turn off and the system will
button below the
corresponding icon
displayed
3
, see "TART W LITE/G2+" user manual
4
.
/G2+ user manual (code 50122
639
)".
2
ART W LITE/G2+
4
( )
DESCRIP
TION
MONITOR
*
A
B
C
J
H
SA
GND
I
HZ
HZ
BUS
BUS
128
codes
SA
DIP 1 to 7
Monitor
GND
address
HZ
DIP 8
HZ
EOL
resistor
BUS
OFF = 0
ON = 1
BUS
J
( )
*
Monitor address (code) setup:
Dip1 Dip7:
-
Sets the monitor address (addresses to
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
Important: Apartment 1 (Dip1 to ON & Dip2-Dip to OFF)
Important: Apartment 2 (Dip1 - Dip to OFF).
1 8
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
Dip 8 a ON
ON
. If the
1
2
3
4
5
6
7
8
Not : e To define whether the monitor is master or slave, entering the corresponding "Special code":
"0550" Master (factory default),
Dip1 to Dip : 7 These assign the address of the monitor to call button on the door panel.
Switches - must remain in the OFF position.
2 7
Apartment 1
on
ON
3
1
2
3
4
5
6
7
8
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitor where the bus cable ends.
Deactivate it only in intermediate monitors.
Dip 8 a ON
ON
1
2
3
4
5
6
7
8
( )
*
For more information, see "TART 4
https://doc.golmar.es/search/manual/50122639
EN
MONITOR
A.
Speaker
.
B. Function buttons, access and selection of menu functions.
The function of each button is shown on the monitor screen with an
icon located just above each button (see "TART 4
manual).
D
Press to access 'Doctor mode' function (standby monitor):
- With the special code '0441' (Doctor mode) already entered
(see special codes i
n manual "TART 4
the button for 1 sec. to activate/ deactivate the function.
- The push button led
will blink in white colour and the icon
E
will be displayed in the main menu if the function 'Doctor mode'
is activated and it will turn off if the function is deactivated.
F
C.
Monitor status
LED:
Yellow ON: Standby without notification.
G
Red ON: "Do not disturb" Mode a tivated.
D. 4.3" TFT colour screen.
E. Golmar use.
J
F.
Microphone
.
G.
Raised dots for the visually impaired
In call
/communication
:
Above this raised dot is the 'Start/ nd communication' button.
Above these raised dots is the 'Door opening' button.
H. Configuration switches.
I.
Installation terminals
.
J. Wall mounting connector fixing (x4).
J
Building / Villa (Nexa Door Panel)
1
1 8
2
).
Table of values
7
.
Switch number:
1 2 3 4 5
7
Value when ON
:1 2 4 8 16 32 64
Dip 8 a OFF
ON
1
2
3
4
5
6
7
8
"0551" Slave
1,
"0552" Slave or "0553" Slave .
2
3
Villa (Soul Door Panel)
Note:
See quick guide enclosed with the Kit Soul Art 4W Lite.
Not : e To define whether the monitor is master or slave, entering the corresponding "Special
code": "0550" Master (factory default),
"0551" Slave
1,
Dip 8 a OFF
ON
1
2
3
4
5
6
7
8
W LITE
/G2+ user manual (code 50122
3
W
LITE/G2+"
W
LITE/G2+"
), press
c
people.
E
ON
6
7
1
2
3
4
5
6
7
8
Example: 0+ 0+4+0+ 16+
0+0
= 20
"0552" Slave or "0553" Slave .
2
3
639
)".
EN

Advertisement

Table of Contents
loading