5.3 Setting of basic function

It is possible to readily set the data, using the LE-5AP in substitute for numeric value settng, using 4 keys
arranged on the LE-50PAU.
In addition, it is also possible to set the maximum taper ratio for winding. (See next page.)
Power
Display of version
ON
for several sec.
S P G = * * *
FNC
S P B =
1
S P T =
S S T =
Setting of non-linear compensation.
T 1 0 = * * . *
FNC
2
T 2 0 = * * . *
T 4 0 = * * . *
T 8 0 = * * . *
Setting of input signal level.
I N P U T
FNC
3
V m a x = * . *
Displayed only for pulse / thickness mode.
P U L S E / 1 0 0 R E V
P R = * * * *
Displayed only for winding.
サ イ タ ゛ イ
M A X . T A P E R
設定
セ ッ テ イ
クリア
S E T T N G
Screen displayed
prior to power off
At the first time
* *
* *
S E C
* *
S E C
L E V E L
P U L S E
It is unable to change the setting at the
power amplifire side.
テ ー ハ ° リ ツ
* * * %
It is unable to change the setting at the
power amplifire side.
モニタ
実行
クリア
エラー
Correction
Valid
エ ラ -
E R R O R
The FNC1 to FNC3 keys are acceptable
within any screen.
Stpo gain --------------------0 to 300%
Stop bias --------------------0 to 60%
Stop timer -------------------0 to 30 sec.
Aux.power output timer--0 to 30 sec.
Torque of 10% current ---1.0 to 99.0%
Torque of 20% current ---1.0 to 99.0%
Torque of 40% current ---1.0 to 99.0%
Torque of 80% current ---1.0 to 99.0%
Input signal level ----------0.5 to 8.0V
The freee mode of input signal level is
vallidated when the DIP SW1 is turned
on, SW2 is turned off, SW3 in turned on
and the power source is closed.
Set the number of winding reel pulses /
100 rotations fo reel to 0 to 1,000.
It has been initially set to 100.
The initial value of maximum taper ratio
is 100%, and the effective range is 20 to
500%. (See next page.)
Select the screen or line, using the cursor
key (
When the [ 設定 ] key is pressed with the
"
" mark displayed at the desired line, the
setting mode is turned on, and reset when
Error
the [ CLEAR ] key is pressed.
The setting operation is invalid unless the
[ 実行 ] key is pressed.
If the numeric value is out of applicable set-
ting range, the messege "SETTING ER-
ROR" is displayed when the [ 実行 ] key is
pressed, by which the setting is not accept-
ed.
In such a case, set the correct numeric val-
ue after pressing the [ クリア ] key.