5.4 - Electrical connections

Do
not
connect
water heater to the eletrical line of
a pre-existing water heater which
used the peak / off -peak hours contact.
The heat pump water heater must be permanently
connected to the power supply, and the peak /
off -peak control is done by either programming,
or through the use of an independent cable.
Grounding is mandatory.
Power supply = 230V single phase + ground.
The power supply should comply with all regulations in eff ect in the
country of installation, as well as the NFC 15-100 standard.
A method of disconnection which ensures a total power-cut
in category III conditions should be installed in fi xed piping in
compliance with the installation rules.
Protect the appliance with:
• an 8A all-pole circuit breaker with a minimum 3mm contact
opening.
• a protective 8A circuit breaker with a 30mA diff erential.
If the power supply cable is damaged it must be replaced by the
manufacturer, their customer service technicians, or by a qualifi ed
technician to avoid any risk of injury or danger.
-
INSTALLER
the
heat
pump
DOMESTIC HOT WATER HEAT PUMP 200L & 270L
A. Domestic hot water (DHW)
B.
Domestic cold water (DCW)
C. Underfl oor heating
D. Vers retour générateur de chauff age
E.
Primary circuit mixing valve
F.
To the heating unit return
1.
Stop valve
2.
Pressure reducer
3.
Check valve
4.
Insulating dielectric sleeve (not supplied)
5.
Pressure-relief membrane valve (not supplied)
6.
Run-off siphon
7.
Domestic expansion vessel
8.
Thermostatic mixing valve
9.
Drainage valve
10. Manual purger
11. Water supply circulator
12. Plated heat exchanger (evaporator)
13. Filter (not supplied)

5.4.1 - Remove the top cover