TECHNICAL DATA

TYPE
Thermal power – output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
 The burner meets protection level of IP 40, EN 60529.
 Burner with CE marking in conformity with EEC Directives: Machine Directive 2006/42/EC, Low Voltage
Directive 2014/35/UE and Electromagnetic Compatibility 2014/30/UE .
8
4
3
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pump pressure regulator
5 – Lock-out lamp and reset button
6 – Screws fixing air-damper
7 – Flange with insulating gasket
8 – Vacuum gauge connection
2374
459T55
29 – 69 kW
Kerosene, viscosity 1.5 – 6 mm
Light oil, max. viscosity
Single phase, 230 V ± 10%
Run current 0.85 A – 2850 rpm – 298 rad/s
4 F
Secondary 8 kV – 16 mA
Maximum pressure 14 bar (203 psi)
0.16 kW
Fig. 1
7
6
6
9
EQUIPMENT