Riello 40 GS10D Installation, Use And Maintenance Instructions
Riello 40 GS10D Installation, Use And Maintenance Instructions

Riello 40 GS10D Installation, Use And Maintenance Instructions

Forced draught gas burner
Table of Contents

Advertisement

Quick Links

Installation, use and maintenance instructions
Forced draught gas burner
GB
Two stage operation
CODE
MODEL
TYPE
3757615
RIELLO 40 GS10D
576T1
20063795 (5) - 11/2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 40 GS10D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Riello 40 GS10D

  • Page 1 Installation, use and maintenance instructions Forced draught gas burner Two stage operation CODE MODEL TYPE 3757615 RIELLO 40 GS10D 576T1 20063795 (5) - 11/2021...
  • Page 2 Translation of the original instructions...
  • Page 3: Table Of Contents

    Contents Declarations....................................3 Information and general warnings............................4 Information about the instruction manual ........................4 2.1.1 Introduction.................................. 4 2.1.2 General dangers................................4 2.1.3 Other symbols ................................4 2.1.4 Delivery of the system and the instruction manual...................... 5 Guarantee and responsibility............................5 Safety and prevention................................
  • Page 4 Contents 7.2.2 Safety test - with gas ball valve closed ........................24 7.2.3 Checking and cleaning...............................24 7.2.4 Safety components ..............................25 Opening the burner ..............................26 Faults - Possible causes - Solutions............................27 Tracing the causes of the malfunctioning ........................27 8.1.1 Control box reset................................27 8.1.2 Visual diagnostics ..............................27 8.1.3...
  • Page 5: Declarations

    Electromagnetic Compatibility Such products are marked as follows: CE-0476CT2714 The quality is guaranteed by a quality and management system certified in accordance with ISO 9001:2015. Legnago, 03.05.2021 Research & Development Director RIELLO S.p.A. - Burner Department Mr. F. Maltempi 20063795...
  • Page 6: Information And General Warnings

    Information and general warnings Information and general warnings Information about the instruction manual 2.1.1 Introduction WARNING: MOVING PARTS The instruction manual supplied with the burner: This symbol indicates that you must keep limbs  is an integral and essential part of the product and must not away from moving mechanical parts;...
  • Page 7: Delivery Of The System And The Instruction Manual

    Information and general warnings 2.1.4 Delivery of the system and the instruction  The system supplier must carefully inform the user about: – the use of the system; manual – any further tests that may be required before activating the When the system is delivered, it is important that: system;...
  • Page 8: Safety And Prevention

    Safety and prevention Safety and prevention Introduction The burners have been designed and built in compliance with the type and pressure of the fuel, the voltage and frequency of the current regulations and directives, applying the known technical electrical power supply, the minimum and maximum deliveries for rules of safety and envisaging all the potential danger situations.
  • Page 9: Technical Description Of The Burner

    1/230/50 BASIC DESIGNATION EXTENDED DESIGNATION Models available Designation Voltage Code RIELLO 40 GS10D 1/230/50 3757615 Tab. A Burner categories - Countries of destination Country of destination Gas category SE - FI - AT - GR - DK - ES - GB - IT - IE - PT - IS - CH - NO 2ELL (43,46 ÷...
  • Page 10: Technical Data

    Technical description of the burner Technical data Model RIELLO 40 GS10D Type 576T1 29/41  106 Heat output (Hi) min - max 25.000/35.000  91.000 kcal/h NCV 8  12 kWh/m – 7,000 10,340 kcal/m Fuel Family 2 Pressure: min. 16 mbar – max. 360 mbar...
  • Page 11: Firing Rate

    Technical description of the burner Firing rate The burner output is chosen from within the diagram area The firing rate value (Fig. 2) has been obtained (Fig. 2). considering an ambient temperature of 20°C, an atmospheric pressure of 1013 mbar (approx. 0m above sea level), and with the combustion head WARNING adjusted as shown on page 16.
  • Page 12: Burner Description

    Technical description of the burner Burner description 20065836 Fig. 4 Air dampers 12 Flange Damper fixing screws 13 Pressure test point (+) Pressure test point (-) 14 Combustion head Cover fixing screw 15 Electrode-probe Air pressure switch 16 Gas train elbow Motor 17 7-pole socket for power supply and remote controls Lock-out signal with reset button...
  • Page 13: Control Box (Rmg88.62C2)

    The control box is a safety device! Avoid opening WARNING or modifying it, or forcing its operation. Riello S.p.A. cannot assume any responsibility for dam- age resulting from unauthorised interventions!  All interventions (assembly and installation operations, assistance, etc.) must be carried out by qualified personnel.
  • Page 14: 4.11 Air Damper Servomotor

    Technical description of the burner 4.11 Air damper servomotor Warnings To avoid accidents, material or environmental damage, observe the following instructions! Avoid opening, modifying or forcing the actua- WARNING tors.  All interventions (assembly and installation operations, assistance, etc.) must be carried out by qualified personnel. ...
  • Page 15: Installation

    Installation Installation Notes on safety for the installation After carefully cleaning all around the area where the burner will The installation of the burner must be carried out be installed, and arranging the correct lighting of the environ- by qualified personnel, as indicated in this manual ment, proceed with the installation operations.
  • Page 16: Preliminary Checks

    Installation Preliminary checks 5.4.1 Control of the supply A burner label that has been tampered with, re- moved or is missing, along with anything else that After removing all the packaging, check the integ- prevents the definite identification of the burner rity of the contents.
  • Page 17: Securing The Burner To The Boiler

    Installation Securing the burner to the boiler  Separate the combustion head assembly from the burner body by removing nut 1) and removing the group A)(Fig. 10). Provide an adequate lifting system of the burner.  Fix the group B)(Fig. 10) to the boiler plate 2), inserting the supplied insulating gasket 3).
  • Page 18: Combustion Head Adjustment

    Installation Combustion head adjustment To adjust, proceed as follows:  loosen the screw A)(Fig. 12), move the elbow B) so that the rear plate of the coupling (C) coincides with the set point;  tighten the screw A). Example: S7015 The burner is installed in a 72 kW boiler.
  • Page 19: Gas Feeding

    Installation CAM II SECOND STAGE Micrometric screws Cam V adjusts the position of the 2° stage damper. (Reference value 60°, do not exceed 70°). Do not tamper with this adjustment for any reason. WARNING The adjustment of the 2° stage air is carried out using the damper cover 1)(Fig.
  • Page 20: Gas Train

    Installation 5.10.2 Gas train Supplied separately for its adjustment, see the enclosed instruc- tions. Approved according to standard EN 676 and provided separately The train-burner combination is indicated in Tab. F. from the burner. Connections Code Model Gas train Burner Natural gas ...
  • Page 21: Electrical Wiring

    Installation 5.12 Electrical wiring 5.12.1 Notes on safety for the electrical wiring  The electrical wiring must be carried out with the electrical supply disconnected.  Electrical wiring must be made in accordance with the regulations currently in force in the country of destination and by qualified personnel.
  • Page 22: 5.12.2 Standard Wiring Diagram

    Installation 5.12.2 Standard wiring diagram RMG88.62C2 Connect the 2nd stage thermostat between terminals T6 and T8, re- moving the bridge. 20126552 Fig. 18 Key (Fig. 18) Burner shelf 2nd stage thermostat Air damper servomotor Safety thermostat 1st stage operating signal Fuse 2nd stage operating signal Safety valve...
  • Page 23: Electrical Wiring With Valve Seal Control (Dungs Vps 504)

    Installation 5.12.3 Electrical wiring with valve seal control (DUNGS VPS 504) Connect the 2nd stage thermo- stat between terminals T6 and T8, removing the bridge. D4148 Fig. 19 Key (Fig. 19) 5.12.4 Ionisation current 1st stage operating signal The minimum current necessary for the control box operation is 2nd stage operating signal 3 µA.
  • Page 24: Start-Up, Calibration And Operation Of The Burner

    Start-up, calibration and operation of the burner Start-up, calibration and operation of the burner Notes on safety for the first start-up The first start-up of the burner must be carried out Check the correct working of the adjustment, com- by qualified personnel, as indicated in this manual mand and safety devices.
  • Page 25: Operation Sequence Of The Burner

    Start-up, calibration and operation of the burner Operation sequence of the burner Normal Lockout due to ignition failure Thermostat Motor Ignition transformer 1° stage valve 1° stage flame 2° stage valve 2° stage flame Lockout D4170 max. 3s max. 2s max.
  • Page 26: Maintenance

    Maintenance Maintenance Notes on safety for the maintenance The periodic maintenance is essential for the good operation, Before carrying out any maintenance, cleaning or checking oper- safety, yield and duration of the burner. ations: It allows you to reduce consumption and polluting emissions and to keep the product in a reliable state over time.
  • Page 27: Safety Components

    Maintenance Boiler 7.2.4 Safety components Clean the boiler as indicated in its accompanying instructions in The safety components must be replaced at the end of their life order to maintain all the original combustion characteristics in- cycle indicated in Tab. K. The specified life cycles do not refer to tact, especially the flue gas temperature and combustion cham- the warranty terms indicated in the delivery or payment ber pressure.
  • Page 28: Opening The Burner

    Maintenance Opening the burner Disconnect the electrical supply from the burner by means of the main system switch. DANGER Turn off the fuel interception tap. DANGER Wait for the components in contact with heat sources to cool down completely. If maintenance of the combustion head is required, refer to the in- structions given in “Operating position”...
  • Page 29: Faults - Possible Causes - Solutions

    Faults - Possible causes - Solutions Faults - Possible causes - Solutions Tracing the causes of the malfunctioning The control box features a diagnostics function through which The control box generates a sequence of pulses (1 second any causes of malfunctioning are easily identified (indicator: RED apart), which is repeated at constant 3-second intervals.
  • Page 30 Faults - Possible causes - Solutions 8.1.3 Software diagnostics  Once the button is released, the red LED will flash intermit- tently with a higher frequency: only now can the optical link Gives an analysis of the life of the burner, through optical connec- be activated.
  • Page 31 Faults - Possible causes - Solutions Signal Problem Possible cause Recommended remedy 2 blinks Once the pre-purging The operation solenoid lets little gas through Increase phase and safety time  One of the two solenoid valves does not open Replace them have passed, the burner Gas pressure too low Increase pressure at governor...
  • Page 32 Faults - Possible causes - Solutions Signal Problem Possible cause Recommended remedy No blink The burner does not No electricity supply Close all switches and check connec- start tions A limiter or safety control device is open Adjust or replace Line fuse blocked Replace Defective control box...
  • Page 33: Appendix - Accessories

    Appendix - Accessories Appendix - Accessories Long head kit Standard length Long head length Burner Code (mm) (mm) RIELLO 40 GS10D 3001064 LPG kit Burner Code RIELLO 40 GS10D 3000884 Town gas kit Burner Code RIELLO 40 GS10D 3000891 Conical flame funnel with diffuser disc...
  • Page 36 RIELLO S.p.A. I-37045 Legnago (VR) Tel.: +39.0442.630111 http:// www.riello.it http:// www.riello.com Subject to modifications...

This manual is also suitable for:

576t13757615

Table of Contents