Use these schematics to build custom cables at your own risk. Miswired cables
can cause serious damage to the camera, which is not covered under warranty.
Vision Research recommends only using cables supplied by Vision Research.
PHANTOM T-SERIES BNC CONNECTORS
BNC
1 Trigger
2 TC In
Program-
mable I/O
SDI
POWER CONNECTOR (MALE) (PRIMARY & BACKUP)
Cable 3-pin Fischer Part #SS 104Z040-80
C O N N E C T O R P I N - O U T S
Vision Research, Inc. | Phantom T-Series Camer a Manual
NOMENCLATURE/FUNCTION
Dedicated I/O - Trigger-In / active-low isolated input.
Can be activated by a switch to ground. The trigger pulse
needs to be at least three microseconds long.
Dedicated I/O - Timecode In / can accept IRIG-B and SMPTE
standards.
Programmable I/O ports have a +5V maximum threshold,
input is also compatible with TTL levels and must be properly
terminated (50-ohms). Isolated collector output with 1k pull-up.
75-ohms. Outputs standard HD-SDI signals up to 1080 p60
PIN
NOMENCLATURE/FUNCTION
1
+20–28VDC
2
CHGND / Chassis Ground
3
GND / Power Ground
All pin-out diagrams refer to the connector on the camera body.
Part numbers indicated are for the cable's connector.
ETHERNET CONNECTOR (FEMALE)
Cable 8-pin Fischer Part #SS 103 A058-130
PIN
WIRE
1
Blue/White
2
Blue
3
Brown/White
4
Brown
5
Green/White
6
Green
7
Orange/White
8
Orange
VF PWR CONNECTOR (FEMALE)
Cable 4 pin Hirose part # HR10A-7P-4P
PIN
1
2
3
4
NOMENCLATURE/FUNCTION
MDI2P Media Dependent 2 Positive
MDI2N Media Dependent 2 Negative
MDI3P Media Dependent 3Positive
MDI3N Media Dependent 3 Negative
ETHRXP Ethernet Receive Positive
ETHRXN Ethernet Receive Negative
ETHTXP Ethernet Transmit Positive
ETHTXN Ethernet Transmit Negative
NOMENCLATURE/FUNCTION
GND Chassis Ground
RTALLY Red Tally
GTALLY Green Tally
+12 VDC / up to 1 Amp