Bin Control 2 (Proximity Switch (Mechanical Backup)) - Hoshizaki F-1501MRJZ Instruction Manual

Modular flaker
Table of Contents

Advertisement

2. Bin Control 2 (Proximity Switch (mechanical backup))

1) Make sure the power switch is in the "OFF" position and that the power supply is off.
2) If not already removed, remove the front panel, top panel, and control box cover.
3) Remove the spout spring from the spout. See Fig. 15.
Spout Spring
4) Turn on the power supply. Move the control switch to the "ICE" position, then move the
power switch to the "ON" position.
5) 30 seconds after the upper float switch closes, the control board "GM" LED turns on.
After "GM" LED turns on, press the "SERVICE" button on the control board to bypass
the 5-minute compressor delay. WARNING! Risk of electric shock. Care should be
taken not to touch live terminals.
6) "GM" LED and "COMP" LED are on. Open the spout cover slightly. See Fig. 16.
"GM" LED and "COMP" LED turn off within 10 seconds and the control board sounds a
9 beep alarm. Close the spout cover.
7) Move the power switch to the "OFF" position, then turn off the power supply.
Note: The control board alarm resets when power is turned off.
8) Replace the spout spring in its correct position.
9) Replace the control box cover and top panel in their correct positions.
10) Turn on the power supply. Make sure the control switch is in the "ICE" position, then
move the power switch to the "ON" position to start the automatic icemaking process.
11) Replace the front panel in its correct position.
12) Return to "II.I.2. Post-Startup" and complete final checklist.
Fig. 15
Fig. 16
38
Spout Cover
Spout
Spout Cover
Spout