• Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the
fan blade (if applicable) turns freely.
• Check that the compressor is snug on all mounting pads.
• Flaker and soft cubelet (-SC) models can be installed on an ice storage bin only.
Cubelet models can be installed on either a cubelet-compatible dispenser unit or an ice
storage bin. The ice storage bins listed below are recommended.
Model Number
F-1501M_J(Z)(-C)(-SC)
F-2001M_J(Z)/3(-C)(-SC)
For further options, contact your local Hoshizaki distributor.
• NOTICE! Remote models must be connected to an appropriate remote condenser
unit. The remote condenser units listed below are recommended. Connection to a
different remote condenser unit will void the warranty unless Hoshizaki approves
a different remote condenser unit for your specific application. For further
details, contact your local Hoshizaki distributor.
Model Number
F-1501MRJZ(-C)(-SC)
F-2001MRJZ/3(-C)(-SC)
• On low-side models, an R-404A, R-407A, or R-407F parallel rack system is needed.
See "II.H. Parallel Rack System Connection" for refrigeration circuit details.
C. How to Remove Panels
See Fig. 1
• Front Panel: Remove the screw. Lift up and towards you.
• Top Panel: Lift up at front slightly, push rearward and lift off.
• Side Panels: Remove the screw. Slide forward slightly and lift off.
Bin Width
30" or Wider
Recommended Hoshizaki Remote Condenser Unit
Left Side
Panel
Front Panel
Fig. 1
Recommended Hoshizaki Ice Storage Bin
B-500 Series
URC-14FZ
URC-22FZ
Model Shown: F-1501MWJ
15
Top Panel
Right Side
Panel

Advertisement