ENGLISH IMPORTANT SAFETY INFORMATION Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. Indicates a hazardous situation which, if not avoided, could result in death or WARNING serious injury.
Page 4
ENGLISH WARNING This is a commercial icemaker, and should be destined only to be used for the purpose for which it has been expressly designed. Any other use should be considered improper and therefore dangerous. The manufacturer will not be held liable or responsible for any damage caused by improper, incorrect and unreasonable use.
ENGLISH 1) After removing the packaging, make sure that the icemaker is in good condition. If in doubt, please do not use the icemaker but apply to professionally qualified personnel. 2) Remove the shipping tape holding the door and separator. 3) Remove the protective plastic film from the exterior.
* Icemaking water must be potable water. Where scaling can be caused by water quality, installation of an external filter or softener is recommended. Contact your local water treatment professional or Hoshizaki service agent. * Water supply pressure should be minimum 0.07 MPa (0.7 bar) and maximum 0.8 MPa (8 bar). If the pressure exceeds 0.8 MPa (8 bar), use a proper pressure reducing valve.
ENGLISH Water Supply Tap Dual Check Valve Tap Washer Outlet Hose Inlet Hose Inlet Hose [Connection to the drain] * Hand tighten grey flexible outlet hose (accessory) onto the fitting on the rear of the icemaker as indicated, ensuring rubber washer is correctly positioned to obtain a leak free joint.
ENGLISH Operation Panel [1] Display run: Icemaking oFF: Shut down FUL: Bin full cln: Cleaning [2] Dot Off: Normal mode On: Sanitation mode (*) * After 4 continued hours of inactivity, the icemaker automatically cleans and refreshes the water circuit to prevent bacterial proliferation, keeping it clean and sanitary for longer periods of time.
ENGLISH Code Item Description Default Irradiate UV-LED for set period of time. U.51 UV-LED irradiation time (**) – None or adjustable from 10 to 30 minutes (in 1-minute steps) Irradiate UV-LED in freeze cycle after set period of time. U.52 UV-LED irradiation frequency (**) 120 minutes Adjustable from 30 to 300 minutes (in 10-minute steps)
5) Either mix 3 litres of water with 11 ml of 5.25% sodium hypochlorite solution in a Handle suitable container, or the recommended Hoshizaki sanitiser as directed. 6) Soak a clean sponge or cloth with the solution, and wipe the bin liner, bin door, slope and scoop holder.
Page 12
“run”. 4) When the display changes to “cln”, pour the following amount of solution into the water tank carefully not to overflow it. Water Tank KM-40C-HC: 2.0 litres KM-60C-HC: 2.5 litres KM-80C-HC: 3.0 litres KM-140C-HC: 3.5 litres...
4. WARRANTY Hoshizaki warrants to the original owner/user that all Hoshizaki branded products shall be free of defects in material and/or workmanship for the duration of the “warranty period”. The warranty shall be effective for two years from the date of installation.
ENGLISH Warranty repairs should be completed by an approved Hoshizaki dealer or service agency using genuine Hoshizaki components. To obtain full details of your warranty and approved service agency, please contact your dealer/supplier, or the nearest Hoshizaki Service office: Hoshizaki Lancer...