Number of starts
Grundfos recommends
minimum 1 per year.
Maximum 2 per hour.
Maximum 20 per day.
Grundfos recommends
minimum 1 per year.
Maximum 6 per hour.
Maximum 50 per day.
Grundfos recommends
minimum 1 per year.
Maximum 2 per hour.
Maximum 15 per day.
Grundfos recommends
minimum 1 per year.
Maximum 5 per hour.
Maximum 40 per day.

10. Service

All pumps are easy to service.
Service kits and service tools are available from Grundfos.
The pumps can be serviced at a Grundfos service centre.
If Grundfos is requested to service the pump, Grundfos must be
contacted with details about the pumped liquid, etc. before the
pump is returned for service. Otherwise Grundfos can refuse to
accept the pump for service.
Possible costs of returning the pump are paid by the customer.
Additional service documentation including service videos are
available in Grundfos Product Center > http://product-
selection.grundfos.com/.
DANGER
Electric shock
Death or serious personal injury
Switch off the power supply before starting any work
on the product.
Make sure that the power supply cannot be
accidentally switched on.
DANGER
Toxic or radio active liquid
Death or serious personal injury
If a pump has been used for a liquid which is injurious
to health or toxic, the pump will be classified as
contaminated.
WARNING
Sharp element
Death or serious personal injury
For service - see service instructions. Must be
performed by qualified persons.

10.1 SPE

The following is only valid for SPE pump sets.
DANGER
Magnetic field
Death or serious personal injury
Do not handle the rotor if having a pacemaker.
DANGER
Crushing of hands
Death or serious personal injury
Keep the rotor surroundings free of magnetic objects
and be careful when placing the rotor on a magnetic
surface.
DANGER
Electric shock
Death or serious personal injury
Make sure that motor cable ends are not live before
starting work on the product.
Make sure that the power supply cannot be
accidentally switched on.
In case of unintended water flow through a non-energized pump,
there is a risk that the moving parts of the pump and the motor may
start rotating, and generate voltage over the terminals. The size of
the voltage depends on the rotation speed. Therefore, the motor
terminals must be considered as live until proven otherwise.