2.1.8
This Niftylift contains several hazardous substances such as, but not limited to, battery
hydraulic fluid.
2.1.9
Covers and canopies should remain closed when the Niftylift is in operation. Only trained personnel
should carry out maintenance on the Niftylift, ensuring at all times they protect themselves from
electrical, heat, and mechanical hazards.
2.1.10
Never exceed the maximum platform capacity, as indicated on the decals and machine serial plate.
2.1.11
Only operate the Niftylift on a firm, level surface.
2.1.12
Never position any part of the Niftylift inside the Minimum approach distances (MAD) to above-
ground electrical conductors as listed in the table below. (Reference ISO 18893:2014).
2.1.13
On entering the platform ensure that the drop down entry bar is closed afterwards.
2.1.14
Use of an approved safety belt and lanyard, hard hat, and appropriate safety clothing is mandatory.
Fasten harness to designated harness securing points within the platform and do not remove until
leaving the platform whilst in the stowed position.
2.1.15
2.1.16
Do not use the platform levelling system to artificially increase the outreach of the platform.
2.1.17
Do not use the platform to lift overhanging or bulky items that may exceed the maximum capacity or
objects that may increase the wind loading on the platform e.g. notice boards etc.
2.1.18
The Niftylift shall not be operated from a position on trucks, trailers, railway cars, floating vessels,
scaffolds, or similar equipment unless the application is approved in writing by Niftylift Ltd. in Great
Britain.
English/USA – 05/15
Original instructions
Voltage range (kV)
<0.7
≥0.7 to 7
>7 to 50
>50 to 220
>220 to 500
>500 to 750
>750 to 1000
>1000 to 1250
THIS MACHINE IS NOT INSULATED.
If in doubt, contact the local appropriate governing authority.
Always remain standing within the platform. Do not sit, stand, or climb on the guard
rail, mid rail, boom linkage, or any other object to attempt to increase your height or
reach. KEEP YOUR FEET ON THE PLATFORM FLOOR. The use of planks, ladders,
or any other devices on the Niftylift for achieving additional height or reach shall be
prohibited.
Height Rider/SP Series
Operating & Safety Instructions
MAD (m)
1
1.2
3
4
5
10
13
16
acid