HELIX
If the sprayer is new, no security code is set and
i
the Main Screen will appear at startup. When
setting a security code for the first time, the
"Enter Old Code Number" screen will appear, and
you will need to enter "1111".
Enter the old security code number
to access the screen that allows the
code change. If the wrong code is
entered, the display will continue to ask for the correct code
and the security code cannot be changed.
Enter the new security code. Once
the new code is entered, the display
will automatically ask that the new
code be re-entered for verification.
If the same new code is re-entered,
the display will confirm that the new
code has been accepted and return to the Main Screen. If the
new code is re-entered incorrectly, the display will return to
the "Enter New Code Number" screen and the process will
repeat.
If you forget or misplace your security code, you can call Titan
customer service for assistance.
To inactivate the Anti-Theft Digital Lockout
i
security function, enter "1111" at the "Enter New
Code Number" screen (this is the default code
that leaves the sprayer unlocked). As a result, the
Main Screen will appear at sprayer startup.
If there is no action at any menu screen for 10
i
seconds, the display will go back to the Main
Screen.
ENTER OLD CODE
NUMBER
ENTER NEW CODE
NUMBER
XXXX
RE-ENTER NEW
NUMBER
XXXX
NEW CODE NUMBER
ACCEPTED
4.5

CONTROL DISPLAYS ERROR MESSAGES

The following error message screens appear whenever the
Control Display detects a problem with the system. Once a
problem occurs and the error message appears, the system will
shut down.
Before proceeding, follow the Pressure Relief
Procedure outlined in this manual. Additionally,
follow all other warnings to reduce the risk of
an injection injury, injury from moving parts or
electric shock. Always unplug the system before
servicing!
Check Transducer Screen
The Check Transducer screen appears
when the transducer has become
disconnected or is defective. Take the sprayer to a Titan
authorized service center for repair.
Check Potentiometer Screen
The Check Potentiometer screen
appears when the potentiometer has
become disconnected or is defective. Take the sprayer to a
Titan authorized service center for repair.
Low Voltage Screen
The Low Voltage screen appears
when the sprayer shuts down
because of low input voltage. Check the power supply and
correct the problem. Restart the system.
High Motor Temperature Screen
The High Motor Temperature screen
appears when the temperature of
the motor has risen too high. Take the sprayer to a Titan
authorized service center for repair.
High Mechanical Load
The High Mechanical Load screen
appears when the sprayer shuts
down because of high current or when the sprayer goes into
current fold back mode. Take the sprayer to a Titan authorized
service center for repair.
Imbalance Screen
The Imbalance screen appears when
there is a non-allowable pressure
discrepancy between the (A) and (B) pumps while linked.
If an imbalance occurs, turn both pressure control knobs down
to Min PSI (Bar) then press the #3 key to unlink each pump.
Once the pumps are unlinked, press the #1 key to return to the
Main Screen.
CONTROL PANEL
CHECK
TRANSDUCER
CHECK
POTENTIOMETER
LOW
VOLTAGE
HIGH MOTOR
TEMPERATURE
HIGH MECHANICAL
LOAD
IMBALANCE
3-CLEAR
19