KROHNE 4000 Series Manual page 20

Table of Contents

Advertisement

OPTIMASS 1300C T6 with stainless steel converter housing & without heating
jacket / insulation
Ambient Temp.
T amb °C
OPTIMASS 1300 T6 with stainless steel converter housing and heating jacket / insulation
Ambient Temp.
T amb °C
* Only for equipment configurations according to the table in section 2.2
The cable supplied by KROHNE is designed for a continuous working temperature of up to
105°C. Alternative cabling must be a heat-resistant type with a minimum continuous working
temperature of 80°C.
20
Max. medium
temp. T m °C
40
50
55
Max. medium
temp. T m °C
40
50
55
Temperature Class
45
60
100
130
60
100
130
55
Temperature Class
45
60
95
120
60
75
55
Max. Surface
T6
T5
T4
T3 – T1
T5
T4
T3 - T1
T4 - T1
Max. Surface
T6
T5
T4
T3 – T1
T5
T4 - T1
T4 - T1
Temp. °C
T80
T95
T130
T155
T95
T130
T160
T95
Temp. °C
T80
T95
T130
T155
T95
T110
T130

Hide quick links: