Focus adjustment manual
Step 1: Loosen the focus fixation screw on the underside of the device.
Step 2: Adjust the focus by sliding the lens-housing forward or backward.
Step 3: Tighten the focus fixation screw on the underside of the device.
Zoom adjustment manual
Step 1: Loosen the zoom fixation screw on the underside of the device.
Step 2: Adjust the zoom by sliding the lens-housing forward or backward.
Step 3: Tighten the zoom fixation screw on the underside of the device.

Interconnecting several devices (master/slave operation)

Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled
with the master unit without the need for a DMX controller. The devices must be set to the corresponding
operating modes.
1
Configure all slave units before connecting the master unit: Set each Slave device to the same DMX
address "A001".
2
Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the
DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been
connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller
to the DMX input of the master unit.
3
Set the master unit to the desired operating mode, either Dimmer (Intensity) or Strobe. The
interconnected devices will now operate synchronously.

DMX operation

Setting the number of DMX channels and the DMX starting address
For operation with a controller with DMX512 protocol, the device is equipped with 5 control channels.
However, it can also be switched to a mode with 2 channels if different functions are required. To be able to
operate the device with a DMX controller, the DMX starting address must be set. The starting address
depends upon which DMX controller is being used. Please refer to the controller's documentation.
1
Turn the encoder until you reach the DMX start address "A001". Confirm by pressing the encoder.
2
Turn the encoder until Mode is indicated in the display. Confirm by pressing the encoder.
3
Then turn the encoder until 2CH (2 DMX channels) indicates in the display. By turning the encoder
further, you can also select 5CH (5 DMX channels). Confirm by pressing the encoder.
4
The display lights up normally when DMX signals are being received. If no control signals are available,
the display will flash.
Note: Please make sure that you do not have any overlapping channels in order to control each device
correctly and independently from any other fixture on the DMX chain. If several devices are addressed to the
same address, they will work synchronously.
Functions in DMX mode
2-channel mode
Channel
Value
1
000 – 255
2
000 – 255
Function
Dimmer 3200K
Total brightness, 0 – 100%, increasing
Dimmer 5600K
Total brightness, 0 – 100% increasing
22/24