EuroLite LED PFE-60 CW User Manual page 21

Profile spot
Table of Contents

Advertisement

Available languages

Available languages

CCT
In CCT mode, you can set the fixture color temperature.
Press the encoder and then turn the encoder until the CCT function is indicated in the display. Confirm by
pressing the encoder. Now you can set the desired color temperature from 3200K – 5600K by turning the
encoder. Confirm by pressing the encoder.
Intensity
In Intensity mode, you can set the total brightness.
Press the encoder and then turn the encoder until the Intensity function is indicated in the display. Confirm
by pressing the encoder. Now you can set the desired brightness from 000 – 255 by turning the encoder.
Confirm by pressing the encoder.
DIM Strobe
Strobe
In Strobe mode, you can set the speed for strobe.
Press the encoder and then turn the encoder until the Strobe function is indicated in the display. Confirm by
pressing the encoder. Now you can set the desired speed from 000 – 012. Confirm by pressing the encoder.
Curve
With this function, you can set various dimmer curves.
Press the encoder and then turn the encoder until the function Curve appears in the display.
Linear: the increase in light intensity appears to be linear as DMX value is increased. Confirm by pressing
the encoder. Turning the encoder takes you to a further dimmer curve.
Exponential: light intensity control is finer at low levels and coarser at high levels. Confirm by pressing the
encoder. Turning the encoder takes you to a further dimmer curve.
Logarythmic: light intensity control is coarser at low levels and finer at high levels. Confirm by pressing the
encoder. Turning the encoder takes you to a further dimmer curve.
S-type: light intensity control is fine at low levels and high levels and coarser at medium levels. Confirm by
pressing the encoder.
Curve
50C
Curve
50C
Curve
50C
Curve
50C
Linear
Exponential
Logarythmic
S-type
Mode
This function is used to set the DMX channel mode.
Set the DMX start address A001 by turning the encoder.
Press the encoder and then turn the encoder until the default setting mode 2CH appears in the display. By
pressing the encoder, the desired mode is indicated in color. By turning the encoder, you can now also
select 5CH mode. Confirm by pressing the encoder.
PWM rate
With this function you can change the frequency of the pulse width modulation.
Press the encoder and then turn the encoder until the default setting of 1200 Hz is indicated in the display.
Confirm by pressing the encoder.
By turning the encoder you can now change the pulse width modulation from 800 Hz – 25000 Hz. Confirm by
pressing the encoder.
21/24
00147099, Version 1.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Led pfe-60 ww

Table of Contents