IBC SL 28-160 Installation And Operating Instructions Manual page 2

Modulating gas boiler
Table of Contents

Advertisement

WARNING
If the information in this
manual is not followed
exactly, a fire or explosion
may result causing property
damage, personal injury, or
loss of life.
HAZARDS &
PRECAUTIONS
DANGER
Points out an immediately
hazardous situation which
must be avoided in order
to prevent serious injury or
death.
WARNING
Points out a potentially
hazardous situation which
must be avoided to prevent
serious injury or death.
CAUTION
Points out a potentially
hazardous situation which
must be avoided to prevent
possible moderate injury and/
or property damage
NOTE
Points out installation,
maintenance and operation
details that will result in
enhanced efficiency, longevity
and proper operation of your
boiler.
2
SL 28-160 MODULATING GAS BOILER
SAFETY CONSIDERATIONS
Installation, start-up and servicing of IBC boilers must be done with due
care and attention, and should only be performed by competent, qualified,
licensed and trained heating technicians. Failure to read and comply with
all instructions and applicable National and local codes may result in
hazardous conditions that could result in property damage and injury to
occupants which in extreme cases might result in death.
SPECIFICATIONS
SPECIFICATION
CSA Input (Natural Gas or Propane*) - MBH
CSA Input (Natural Gas or Propane*) - kW
CSA Output - MBH
CSA Output - kW
A.F.U.E.
Minimum gas supply pressure (Natural Gas or Propane)
- inch w.c.
Maximum gas supply pressure (Natural Gas or Propane)
- inch w.c.
Power use (120Vac/60Hz) @ full fire - Watts (without
pumps)
Weight (empty) - lbs/Kg
Pressure vessel water content - USG/Litres
Maximum boiler flow rate - USgpm
Minimum boiler flow rate - USgpm
Maximum operating water pressure† - psig
Minimum water pressure - psig
Approved installation altitude - ASL
Ambient temperature - Low (°F-°C)
Ambient temperature - High (°F-°C)
Max. relative humidity (non-condensing)
Minimum water temp.
Maximum water temp. (electronic hi-limit)
Maximum water temp. (mechanical hi-limit)
Max. ΔT - supply/return (electronic fence)
Maximum equivalent vent length
Each side (vent & air intake)
(Natural Gas or Propane)
Air intake options: either direct vent or indoor supply
*
Natural Gas boilers require a Propane conversion kit - Part #P213 to be ordered separately if converting a Natural Gas boiler to
Propane. Propane (LP) boilers require a Natural Gas conversion kit - Part #P214 to be ordered separately if converting a Propane
boiler to Natural Gas.
† boilers are shipped with 30 psig pressure relief valve
Supplied with the boiler - The IBC boiler is shipped with an accessory parts kit
consisting of the following items:
1 x Wall mounting bracket
1 x Condensate trap assembly
1 x 30 psig pressure relief valve
SL 28-160
28 - 160
8.2 - 47
26.2 - 147
7.7 - 43
95%
5
14
73
102 / 46.3
3.2 / 12.2
19
4
30
8
0 - 12000'
32°F / 0°C
122°F / 50°C
90%
34°F / 1.1°C
190°F / 87.8°C
200°F / 93.3°C
40°F
- 2"
35'
- 3"
170'
1 x Outdoor temperature sensor
6 x 1/4" x 2 1/2" Lag screws/w flat
washers
INSTALLATION AND OPERATION INSTRUCTIONS