13. Troubleshooting

Fault
Possible cause
No supply voltage.
Insufficient supply voltage.
The compressor
does not start.
Outside temperature is too low.
Motor is overheated.
The non­return valve leaks.
The compressor
starts but there is no
The seals are damaged.
pressure.
The drain plug for condensation water (1)
leaks.
The hose connections have a leak.
The compressor
starts, pressure is
shown on the pres­
A quick­lock coupling has a leak.
sure gauge, but the
tools do not start.
Insufficient pressure set on the pressure
regulator (7).
WARRANTY:
Thank you for choosing an ADEO power tool. These products are manufactured to high quality standards and are guar­
anteed against manufacturing defects for 24 months from the date of purchase for private use.
This guarantee does not affect your statutory rights. In the event of a malfunction of your power tool (defective, missing
part, etc.), please contact the customer service.
ADEO service address:
135 RUE SADI CARNOT CS00001,
59790 RONCHIN,
FRANCE
Normal wear and tear, including wear and tear on accessories, is excluded from the guarantee. The product is guaranteed
for 24 months if it is used in normal household use. The warranty claim expires if the product has been overloaded or
neglected, has been used improperly or repairs have been carried out by an unauthorised representative. The warranty
claim expires both with daily continuous operation and with commercial or industrial use. Due to continuous product im­
provements, we reserve the right to change product data without prior notice.
Remedy
Check the supply voltage, the power plug and
the socket­outlet.
Make sure that the extension cable is not too
long. Use an extension cable with large enough
wires.
Never operate with an outside temperature of
below +5° C.
Allow the motor to cool down. If necessary,
remedy the cause of the overheating.
Have a service center replace the non­return
valve.
Check the seals and have any damaged seals
replaced by a service center.
Tighten the screw by hand. Check the seal on
the screw and replace if necessary.
Check the compressed air hose and tools and
replace if necessary.
Check the quick­lock coupling and replace if
necessary.
Increase the set pressure with the pressure
regulator.
GB | 35