EN 22
5.
EJ3.0U PA
Service Modes, Error Codes, and Fault Finding
PDP SDI
[42"/50" V5, W1 & W2, or 63" V4]
action holder: MIPS
Active
action holder: St-by
autonomous action
Mute all sound outputs.
Switch reset-audio and sound-enable
lines "high"
Blank PDP display
Mute all video outputs
Wait 600ms to prevent image
retention
(display error)
Switch "off" LVDS signal
(PNX2015)
Switch the SDI Picture flag "high" to prevent
testpattern display in semi-standby mode
Semi Standby
G_15960_132.eps
020307
Figure 5-10 "Active" to "Semi Stand-by" flowchart