Operating Instructions

Compressor Mounting

Portable compressors, which are modified to remove the running gear and mount the machine
direct to trailers, truck beds or frames, etc. may experience failure of the enclosure, frame,
and/or other components. It is necessary to isolate the compressor package from the carrier
base with a flexible mounting system. Such a system must also prevent detachment of the
package from the carrier base in the event the isolators fail. Contact Ingersoll Rand
representative for flexible mounting kits.
Warranty does not cover failures attributable to mounting of the compressor package to the
carrier base unless it is an Ingersoll Rand provided system.

For Remote Fueling

— one 3/4" female connector (supply)
— one 3/4" male connector (return)
Open rear door and locate fuel manifold.
Lever handle in the vertical position permits fueling from onboard tanks.
Lever handle in the horizontal position allows remote fueling.
Do not connect the air discharge on this unit onto a common header with
any other unit of any description, or any other source of compressed air,
without first making sure a check-valve is used between the header and
the unit. If this unit is connected in parallel with another unit of higher
discharge pressure and capacity, a safety hazard could occur in a
back-flow condition.
Unrestricted air flow from a hose will result in a whipping motion of the
hose which can cause serious injury or death. A safety device must be
attached to the hose at the source of supply to reduce pressure in case
of hose failure or other sudden pressure release. Reference: OSHA
regulation 29 CFR Section 1926.302 (b).