Installation Requirements

The ideal mounting position for the heater is on the ceiling directly above the area to be heated. If this is not possible, the
heater can be mounted on a wall and angled downwards. In this situation, ensure the mounting height is in the range of 2.1m
to 2.4m and the table is within 1.0m of the wall. Mounting heights above 2.5m are not recommended. Mounting heights
between 2.3m - 2.4m are optimal.
Electrical connections/GPO's should not be located at the back of the heater. They should be located outside the physical
footprint of the units to minimize heat build-up behind the units.
If the heater is to be mounted on an incline (e.g. vaulted ceiling), ensure the electrical connection is located at the lowest point
of the heater.
Heater can be plugged directly into a standard 10Amp GPO. Heater can also be hardwired by a licensed electrician.

Incorrect Installation

Correct Installation
The heating surface must never be directed toward the ceiling