Page 1
Installation and Maintenance Instructions Screw Vacuum Pumps COBRA BC 0100 F Version with Variable Frequency Drive Busch Manufacturing Korea, Ltd. 189-51, Soicheon-ro, Majang-myun Icheon-si, Gyunggi-do, 467-813 Republic of Korea 0870751579 / 190321 / Original instructions / Subject to change without notice...
Discharge connection ..... 10 Congratulations on your purchase of the Busch vacuum pump. With Cooling water connection ....11 watchful observation of the field’s requirements, innovation and steady...
Operating principle national safety regulations and that all applicable safety measures The COBRA BC 0100 F vacuum pumps are COBRA NW screw vacuum are followed. pumps with cooling water and nitrogen circuits.
If you have any doubts, For a correct purge execution, the shut-off valve at the inlet flange contact your Busch representative. must be closed. The purge cycle lasts about 30 min. Safety information (Programmable time in the basic parameters).
Type 4 l If ok, check the wiring system from the terminal box motor to the KDP1 contactor. If ok, call the BUSCH Semicon service team in Equipment is energized. Energized circuits are exposed and inadvertent charge of the maintenance of the pumps.
Emergency stop Information over the lubricants Busch YLC 250 B n°.-art. 0831 131 400 (0.5l of Busch YLC 250 B ) Quantity: BC 0100 F : 0,12 l Replacement: After 16'000 h (see Maintenance chapter, page 14) Position of the pump gravity center...
l Switch off the water and nitrogen quick connections (inlet first, then outlet) WARNING l Put the label or warning board “Maintenance processing” on or Any disassembly of the vacuum pump should only be carried out by next to the pump staff trained for this purpose.
Removal of the pump Transport Before starting a vacuum pump that has been stored outside the The COBRA BC vacuum pumps are tested and checked in our factory building for a while, the vacuum pump must be moved to a room with before careful packing.
NOTE: In order to ensure the fixation of the pump to the ground, it is vacuum pump. If you have any doubts, contact your Busch possible to use again the four yellow brackets that were removed at representative.
Make sure that the drive of the vacuum pump is not disturbed by Motor of screw pump COBRA BC 0100 F is connected at factory. any electric or electromagnetic interferences. If you have any...
NOTE: It is easier to switch on the vacuum pump with cold oil when the intake line is not closed or when the intake flange is not covered by The information concerning the use of the Busch PLC and the Busch a rubber plate.
Measure the working current of the motor and save it as reference CAUTION value for all future maintenance and repair work The COBRA BC 0100 F vacuum pumps are always delivered without Recommendations on operation oil and without cooling water.
Inspect the vacuum pump for oil leaks - if there are leaks, repair If this form has not been filled in completely and signed, the the vacuum pump (Busch) vacuum pump may not be dismantled. Maintenance...
Make sure that the vacuum pump has been switched off and that l Drain the oil (see “Draining the oil”) it cannot be switched on again accidentally l A main inspection of the vacuum pump (Busch) l Unscrew the oil fill plug (OFP) Lock Out/ Tag Out procedure...
Oil change CAUTION DANGER Only fill in oil through the oil filler opening. l Unscrew the oil fill plug (OFP) If the vacuum pump has pumped gases that were contaminated with foreign bodies that are hazardous to health, the oil is also l Fill in oil up to the middle of the oil sight glass contaminated with these foreign bodies.
Before work begins, the operator of the vacuum pump must fill in a Busch service will only accept vacuum pumps that come with a form or a “Declaration of Decontamination” that provides completely filled in and legally binding signed form.
Oil type/ quantity Oil type l Make sure that the oil type corresponds to specification: Busch YLC 250 B, Art. No. 0831 131 400 (0,5 l @ 1 kg) – WARNING The use of chemically contaminated or polluted oil can lead to hazardous pump conditions which could cause personal injury.
Technical data Technical data BC 0100 F Nominal suction capacity /h (cfm) 100 (59) Ultimate pressure hPa(mbar)/ mTorr 0,01/ 7,5 Nominal motor rating Power consumption at ultimate pressure Nominal motor speed 3000 Noise level (EN ISO 2151) dB(A) <58 Ambient temperature °C (°F) 0-40 (32-104) Maximal counter pressure...
EU-Declaration of Conformity This Declaration of Conformity and the CE-mark affixed to the nameplate are valid for the machine within the Busch scope of delivery. This declaration of Conformity is issued under the sole responsibility of the manufacturer. When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating company, too) must conduct the conformity assessment process for the superordinate machine or plant, issue the Declaration of Conformity for it and affix the CE-mark.
Page 24