Download Print this page

NEC Express5800/T120h Manual page 51

Hide thumbs Also See for Express5800/T120h:

Advertisement

P.83
From the System Utilities, select "System
(3) Memory ADDDC
Configuration > BIOS/Platform Configuration
function
(RBSU) > System Options > Memory
Operations" to set "Advanced Memory
Protection" to "Fault Tolerant Memory
(ADDDC)".
P.83
The DIMM compatible with the memory
(3) Memory ADDDC
ADDDC function is "N8102-709", "N8102-
function - Note
711", and "N8102-712".
P.118
*3 A maximum of 1 battery can be
1.16.2 Supported PCI
implemented per device
cards and available
slots
P.134
1.21.2 Installing N8103-198 Extension
1.21.2 Installing
Battery in a Normal Setting
N8103-198 Extension
Battery in a Normal
Setting
P.137
●T-10 hexalobular driver
1.22.1 Installing the
●Optical disk drive cable kit
Internal Drive DVD-
ROM N8151-
137/DVD-Super
MULTI N8151-138
P.139
7. Connect the optical disk drive connector to
1.22.1 Installing the
the onboard SATA port 5 connector on the
Internal Drive DVD-
motherboard with the SATA cable for optical
ROM N8151-
disk drive (K410-375 (00)).
137/DVD-Super
Wire the cables as shown below.
MULTI N8151-138
P.141
If the optional RAID Controller (N8103-189/
1.23.1 Notes on
195) is used, the RAID System cannot be built
Building RAID System
in RAID5/RAID6/RAID50/RAID60.
P.204
Not included / Registered DIMM: 768GB (24x
1. Specifications -
32GB), Load Reduced DIMM: 1.5TB (24x
Memory - Standard /
64GB)
Maximum
P.204
DDR4-2666 Registered DIMM (8/16/32GB),
1. Specifications -
DDR4-2666 Load Reduced DIMM (64GB)
Memory - Memory
module
Error
(K410-375(00))
The minimum number of hard
disk drives required to set up
a RAID System
RAID level
N8103-
189/195
190/191/196/201
RAID 0
1
RAID 1
2
RAID 5
RAID 6
RAID 10
4
RAID 50
RAID 60
From the System Utilities, select "System
Configuration > BIOS/Platform Configuration
(RBSU) > Memory Options" to set
"Advanced Memory Protection" to "Fault
Tolerant Memory (ADDDC)".
The DIMM compatible with the memory
ADDDC function is "N8102-
709/711/712/713".
*3 A maximum of 1 battery can be
implemented per system
1.21.2 Installing N8103-203 Extension
Battery in a Normal Setting
●T-15 hexalobular driver
●Internal DVD Drive Installation Kit
(N8154-122)
7. Connect the optical disk drive connector to
the onboard SATA port 5 connector on the
motherboard with the SATA cable for
Internal DVD Drive Installation Kit (N8154-
122).
For the wireing of cables, refer to the
diagram below.
If the optional RAID Controller (N8103-189/
195) is used, the RAID System cannot be built
in RAID6/RAID50/RAID60.
RAID level
N8103-
1
RAID 0
2
RAID 1
3
RAID 5
3
RAID 6
4
RAID 10
6
RAID 50
6
RAID 60
Not included / Registered DIMM: 768GB (24x
32GB), Load Reduced DIMM: 3.0TB (24x
128GB)
DDR4-2666 Registered DIMM (8/16/32GB),
DDR4-2666 Load Reduced DIMM
(64/128GB)
- 51 -
Correct
The minimum number of hard
disk drives required to set up
a RAID System
N8103-
N8103-
189/195
190/191/196/201
1
1
2
2
3
3
4
4
4
6
8

Advertisement