Hearth Extension - Heat & Glo COSMO-I30-IFT Installation Manual

Hide thumbs Also See for COSMO-I30-IFT:
Table of Contents

Advertisement

Mantels - Combustible
Measurement
from surround
opening.
Figure 8.3 Minimum Vertical and Maximum Horizontal
Dimensions - Combustible
B. Hearth Extension
YES
Flooring & Hearth Material
Figure 8.5 Flooring & Hearth Material
Heat & Glo • COSMO-I30-IFT, COSMO-I35-IFT Installation Manual • 2535-980 Rev. V • 10/23
12 in.
12 in.
Measurement to bottom
of appliance:
= 32-3/4 IN. (30")
= 36-1/4 IN. (35")
SURROUND
Flooring & hearth material must remain below the bottom of surround
1/2 in.
Figure 8.4 Minimum Required 1/2 in. Gap to Bottom of Front
• All flooring and hearth material must remain below the
bottom of the surround. See Figure 8.5.
• Combustible flooring may be located in front of the
appliance. Exception - no vinyl / adhesive flooring. See
Figure 8.6.
• 1/2 inch gap under the bottom of the front must be
maintained. See Figure 8.4.
• A minimum 1/4 inch gap from the bottom of the appliance
to the metal floor of the solid fuel firebox is REQUIRED.
See side view in Figure 8.7.
• Combustible flooring underneath the appliance is
acceptable with a 1/4 inch gap. See Figure 8.7.
NO
Flooring & Hearth Material
SURROUND
35