Download Print this page

Omron E3X-NA11 Instruction Manual page 40

User-friendly fiber-optic amplifier
Hide thumbs Also See for E3X-NA11:

Advertisement

E3X-NH
Installation
J CUTTING FIBER
Insert a fiber into the Fiber Cutter and determine the length of the
fiber to be cut.
Press down the Fiber Cutter in a single stroke to cut the fiber.
An insertion mark can be placed on the fiber to serve as a
reference when inserting the fiber into the Amplifier. Use the
following procedure.
Confirm through the Cutter hole that the fiber is inserted beyond
the insertion mark hole so that the insertion mark is properly
indicated, and then press firmly down on the Cutter.
(2)
(1)
Insert the fiber into the Amplifier up to the insertion mark. Proper
fiber performance will not be achieved unless the fiber is inserted
all the way to the insertion mark. (This method is applicable to
standard, 2.2-mm-diameter fibers only.)
J FIBER CONNECTION OR
DISCONNECTION PROCEDURES
The E3X-NH Amplifier has a lock button. Follow these steps to
connect or disconnect the fibers to (or from) the E3X-NH
Amplifier:
Note:
The fiber must be locked or released in a temperature
range of --10°C to 40°C (14°F to 104°F).
Connection
Lock button
Fiber insertion mark
Fiber
1. After cutting the fibers (using the E39-F4 Fiber Cutter), place
an insertion mark on the fiber so that it can be correctly in-
serted into the Amplifier.
2. Insert the fiber into the Amplifier up to this insertion mark.
3. Press the lock button to lock the fiber in that position.
E3X-NH
13

Advertisement