Download Print this page

Omron E3X-NA11 Instruction Manual page 14

User-friendly fiber-optic amplifier
Hide thumbs Also See for E3X-NA11:

Advertisement

E3X-NA
Mounting the Fiber Unit
I
Tightening Force
The tightening force applied to the Fiber Unit should be as shown
below.
Screw-Mounting Model
Spring mounting clip
Toothed washers
Nuts
(attachment)
Fiber Units
Clamping torque
M3/M4 screw
0.78 N·m max.
M6 screw/
0.98 N·m max.
6-mm dia. cylinder
1.5-mm dia.
0.2 N·m max.
cylinder
2-mm dia./3-mm dia.
0.29 N·m max.
cylinder
E32-T12F 5-mm dia.
0.78 N·m max.
Teflon model
E32-D12F 6-mm dia.
Teflon model
E32-T16
0.49 N·m max.
E32-R21
0.59 N·m max.
E32-M21
Up to 5 mm to the tip: 0.49 N·m max.
More than 5 mm from the tip: 0.78 N·m max.
E32-L25A
0.78 N·m max.
E32-T16P
0.29 N·m max.
E32-T16PR
E32-T24S
E32-L24L
E32-L25L
E32-T16J
E32-T16JR
E32-T16W
0.3 N·m max.
E32-T16WR
Use a proper-sized wrench.
Fiber Connection and Disconnection
The E3X-NA Amplifier Unit has a lock button. Connect or discon-
nect the fibers to or from the E3X-NA Amplifier Unit using the
following procedures:
1.
Connection
Open the protective cover, insert the fibers according to the
fiber insertion marks on the side of the Amplifier Unit, and
lower the lock button.
Lock button
Fiber insertion
10.7 mm
mark
Fiber
2. Disconnection
Remove the protective cover and raise the lock button to pull
out the fiber.
14
Cylindrical Model
Retaining screw
(flat head or sunken head)
(M3 max.)
Insertion position
Unlocked
Locked
Note:
To maintain the fiber properties, confirm that the lock is re-
leased before removing the fiber.
3. Precautions for Fiber Connection/Disconnection
Be sure to lock or unlock the lock button within an ambient
temperature range between −10°C and 40°C.
Cutting Fiber
Insert a fiber into the Fiber Cutter and determine the length of the
fiber to be cut.
Press down the Fiber Cutter in a single stroke to cut the fiber.
The cutting holes cannot be used twice. If the same hole is used
twice, the cutting face of the fiber will be rough and the sensing
distance will be reduced. Always use an unused hole.
Cut a thin fiber as follows:
1. An attachment is temporarily fitted to a thin fiber before ship-
ment.
Thin fiber attachment (E39-F9)
Temporarily fitted
2. Secure the attachment after adjusting the position of it in the
direction indicated by the arrow.
3. Insert the fiber to be cut into the E39-F4.
Three holes for
standard fiber
(2.2-mm dia.)
4. Finished state (proper cutting state)
Approx.
0.5 mm
Note:
Insert the fiber in the direction indicated by the arrow.
E3X-NA
Protective cover
Cutter
(E39-F4)
Two holes for
thin fiber
Insertion direction

Advertisement

loading