Table of Contents

Advertisement

7/13/2019
Selector
No.
1
2
3
4
5
6
7
8
  Selectors 2 and 3: Detection enabled time for CNG and no tone
 After the line is connected via the machine or the external telephone, the machine can detect
a CNG signal or no tone for the time length specified by these selectors.
specified by these selectors becomes effective only when selector 8 of WSW20 is set to "1."
  Selectors 7 and 8: Tone sound monitoring
These selectors set monitoring specifications of the tone sound inputted from the line.
http://slidepdf.com/reader/full/brother-8840d-service-manual
WSW18 (Function setting 3)
Function
Not used.
Detection enabled time for CNG
and no tone
Not used.
Registration of station ID
Tone sound monitoring
Brother 8840D Service Manual
MFC-8440/8840D/8840DN, DCP-8040/8045D/8045DN
Setting and Specifications
No. 2
3
0
0
0
1
1
0
1
1
0:
Permitted
No. 7
8
0
X
1
0
1
1
 A-25
SERVICE MANUAL
:
40 sec.
:
0 sec. (No detection)
:
5 sec.
:
80 sec.
1:
Prohibited
:
No monitoring
:
Up to phase B at the
calling station only
:
All transmission phases
both at the calling and
called stations
The setting
318/361