Safety Information - Pentair HYPRO 9500 Series Installation, Operation, Repair Instructions

Direct and gas engine-driven centrifugal pumps
Table of Contents

Advertisement

1. WARNING: Do Not Pump Flammable or
Explosive Fluids Such as Gasoline, Fuel Oil,
Kerosene, etc. Do Not Use in Explosive
Atmospheres. Components not rated for use
with Anhydrous Ammonia. The Pump Should be
Used Only with Liquids that are Compatible with
the Pump Component Materials. Failure to
Follow this Warning May Result in Personal
Injury and/or Property Damage and Will Void the
Product Warranty.
2. Be sure all exposed moving parts, such as PTO
shafts and adapters, are properly shielded or
guarded and that all coupling devices are securely
attached before applying power.
3. Pumps mounted directly onto PTO shaft or other
power shaft must be prevented from rotating with
the power shaft. Pump must float freely on the
power shaft and must not be tied rigidly to
equipment on which it is mounted.
4. DO NOT EXCEED recommended speed, pressure
and temperature (140˚ F) for pump and equipment
being used.
5. BEFORE SERVICING, disconnect all power, make
sure all pressure in the system is relieved, drain all
liquids from the system and flush. On gas engine-
driven models, remove the spark plug wire from the
spark plug before servicing the pump or engine.
1. Always drain and flush pump before servicing or
disassembling for any reason (see instructions).
2. Always drain and flush pumps prior to returning unit
for repair.
3. Never store pumps containing hazardous chemicals.
This manual will cover the installation of the basic drive configurations available for Hypro direct-drive centrifugal
pumps. Consult the manufacturer of your tractor, motor or engine for additional information. Read all instructions
and general safety information before attempting to install or operate the pump.
Series 9200 Pedestal-Mounted
Centrifugal Pumps
Mounting Belts and Pulleys
Mount pulleys as close to pump and motor engine shaft
bearings as possible. Check alignment with a straight
edge as shown in Fig. 1. Make sure that belt has proper
tension. (Too much tension will cause bearing wear; too
little will cause slippage.) See Fig. 2. Check with belt
and pulley sources for specific recommendation.

Safety Information

Hazardous Substance Alert
Drive Source Installation
Belt/Pulley Drive Installation
- 2 -
- 2 -
6. Secure the discharge lines before starting the pump.
An unsecured line may whip, causing personal injury
and/or property damage.
7. Check hose for weak or worn condition before each
use. Make certain that all connections are tight and
secure.
8. Periodically inspect the pump and the system
components. Perform routine maintenance as
required (see Maintenance section).
9. Protect pump from freezing conditions by draining
liquid and pumping rust-inhibiting antifreeze solution
through the system, coating the pump interior.
10. Do not operate a gasoline engine in an enclosed
area. Be sure the area is well ventilated.
WARNING: Gasoline is a Highly Combustible Fuel.
The Improper Use, Handling, or Storage of Gasoline
Can be Dangerous. Never Touch or Fill a Hot
Engine.
11. Use only pipe, hose and fittings rated for the
maximum psi rating of the pump.
12. Do not use these pumps for pumping water or other
liquids for human or animal consumption.
WARNING: Pump must not be run dry.
4. Before returning pump for service/repair, drain out
all liquids and flush unit with neutralizing liquid.
Then, drain the pump. Attach tag or include written
notice certifying that this has been done. Please
note that it is illegal to ship or transport any
hazardous chemicals without United States
Environmental Protection Agency Licensing.
Figure 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hypro 9200 seriesHypro 1536 seriesHypro 1500 seriesHypro 1551 seriesHypro 9263s-crHypro 9263c-cr ... Show all

Table of Contents