1. Positive terminal
2. Negative terminal
3. No connect
3.
Install the power connector on the front panel of the NI-7932R.
4.
Turn on the external power source(s).

Powering on the NI-7932R

When you apply power for the first time to the NI-7932R, the controller boots into safe mode.
The POWER LED illuminates, the STATUS LED illuminates briefly, and then the STATUS
LED blinks twice every few seconds.
After you install software on the controller, subsequent reboots will boot the controller into the
NI Linux Real-Time operating system.
You can optionally configure the NI-7932R to launch an embedded stand-alone LabVIEW
Real-Time application each time you boot the controller.

STATUS LED

The STATUS LED is off during normal operation. The NI-7932R indicates specific error
conditions by flashing the STATUS LED a certain number of times every few seconds, as
shown in the following table.
LED State
2 flashes every few
seconds
3 flashes every few
seconds
1
There is no software installed, which is the out-of-box state, or the
controller has detected an error in its software.
An error can occur when an attempt to upgrade the software is
interrupted. Refer to the MAX Help for information about reinstalling
software on the controller.
The controller is in safe mode. Refer to the MAX Help for
information about safe mode.
Indication