Do you have a question about the 417Li and is the answer not in the manual?
Questions and answers
Peter Kraemer
March 26, 2025
My Solo 417Li will not work. It will turn on and only hum. At the lower (power) level it hums litter.
1 comments:
Mr. Anderson
May 14, 2025
If your Solo 417Li only hums and does not work properly, the issue could be that the pump is running dry due to an empty spraying agent tank. This can cause damage to the pump. It may also be due to low battery power, especially if the operating pressure cannot be maintained. In this case, recharge the battery and ensure the tank is not empty before use.
Page 1
Pressure sprayer with Original instructions rechargeable battery Instruction manual Important! Impo Impo port port rtan rtan ant! ant! Read this instruction manual carefully Read inst stru ruct ctio manu nual aref eful ully before first operation and strictly befo fore irst pera rati...
Page 2
Your authorised SOLO dealer will be glad to assist Wear the prescribed protective clothing. you with any questions. Information about material ingredients Wear protective gloves.
Table of contents 1 Wearing parts / Warranty ......................... 3 1.1 Wearing parts 3 1.2 Warranty 3 2 Safety regulations ............................ 3 2.1 Correct use / areas of application 3 2.2 General safety instructions 4 2.3 Work clothing / personal protection equipment (PPE) 4 ...
1 Wearing parts / Warranty / 2 Safety regulations 1 Wearing parts / Warranty 2 Safety regulations 1.1 Wearing parts 2.1 Correct use / areas of application Various parts are subject to application-specific This pressure sprayer must only be used for the wear or to normal wear and must be replaced in purpose of applying approved liquid plant good time if necessary.
SOLO dealer. He also has access to the nece- The operating instructions must be kept available ssary spare parts lists, from which the required at all times wherever the device is used or stored.
The charger is only designed to recharge the Never allow children or anybody who is not rechargeable battery that is supplied by SOLO familiar with handling this type of spraying agent for this pressure sprayer. Ensure that the battery to handle the spraying agent.
3 Specification 3 Specification Spraying agent tank Max. fill volume 18 l [4.76 gal] Tank volume 19 l [5.02 gal] Filling strainer mesh aperture 1.65 mm [0.065"] Residual volume not properly discharged by the device < 280 ml [9.47 oz] Operating pressure with standard nozzle Setting I Approx.
4 Type plate / 5 Operating and functional components 4 Type plate a: Name and address of the manufacturer SOLO Sprayers (Hefei) Co.,Ltd. No. 718-6 Peng Lai Road Eco. & Tech. Development A b: Product designation Hefei China Anhui c: Type designation "Typ"...
Page 10
5 Operating and functional components View: top, solution tank opened 1. Solution tank 2. Screw cap 3. Filling strainer 4. Fill level markings 5. Spray tube holder 6. Strap holder (carrying straps) 7. High-pressure hose 8. Hand valve 9. Pressure gauge View: right hand side, lower part 10.
6 Preparing the device for use 6 Preparing the device for use 6.2 Spray nozzle, filter element and filling strainer 6.1 Assembly & Firmly screw the nozzle attachment (11) with the O-Ring (10x2 mm) hand-tight onto the spray tube. Do not use any tools! At the factory, a flat jet nozzle 03-F80 blue (a) is assembled as the standard nozzle.
6 Preparing the device for use / 7 Mixing spraying agents and filling the spraying agent tank 6.4 Adjusting the carrying straps When handling the spraying agents, always follow the safety instructions of these Clip the carrying straps into the clips (6) on both operating instructions (pay special attention to sides and lift the pressure across your shoulders.
If the strainer is damaged, replace it by a genuine changed. SOLO replacement part (part no.: 13269, mesh aperture: 1.65 mm [0.0650"]). Avoid any direct contact of the filling hose and the contents of the spraying agent tank.
8 Using the pressure sprayer Ensure that you only wet what is in fact intended The red clip can be used to secure the shut-off valve in its rest position to prevent accidental to be covered with spraying agents. spraying.
(including the support frame), if any of the adjust- ment settings are incorrect or if the equipment is not working properly in any way. In this event have the device checked by an autorised SOLO workshop. 9.3 Checking the spray nozzles and the filter...
Rinse the nozzle attachment with clean water. The replacement glass fuse 6x30 mm 10A (part no.: Disassemble the nozzle attachment (11). 11358) can be ordered at your local SOLO dealer. Clean the filling strainer, the O-rings, the filter Replacing the fuse: element and the spray nozzle with clean water ...
(including the support frame), if any of the adjustment settings are incorrect or if the equipment is not working properly in any way. In this event have the device checked by an autorised SOLO workshop. If you have any questions please refer to your authorised SOLO dealer.
12 Specification of spray nozzles 12 Specification of spray nozzles Pump Delivery Spraying Spray- toggle l/min pressure Specification Part no. switch [USgal/min] bar [psi] angle Applications Hollow cone jet 13203 0.71 [0.19] 3.54 [51.3] 50–70° For treatment of 1 mm [0.039"] + 13202 II * –...
Page 20
SOLO Sprayers (Hefei) Co.,Ltd. No. 718-6 Peng Lai Road Eco. & Tech. Development Area 230601 Hefei Anhui China Tel: +86-551-68676166 Fax:+86-551-68675166 www.solo-sprayers.com...
Need help?
Do you have a question about the 417Li and is the answer not in the manual?
Questions and answers
My Solo 417Li will not work. It will turn on and only hum. At the lower (power) level it hums litter.
If your Solo 417Li only hums and does not work properly, the issue could be that the pump is running dry due to an empty spraying agent tank. This can cause damage to the pump. It may also be due to low battery power, especially if the operating pressure cannot be maintained. In this case, recharge the battery and ensure the tank is not empty before use.
This answer is automatically generated