Wiring Diagrams; External Wiring; Other Devices; Otbus Connection - Riello Vokera VISION PLUS 20 S User Instructions

High efficiency system boiler
Table of Contents

Advertisement

9

WIRING DIAGRAMS

NOTE
Please refer to 3 - 3E and use the appropriate PPE when
carrying out any of the actions or procedures contained within
this section.
9.1

EXTERNAL WIRING

TExternal controls must to be added to the system and they must be
connected to the appliance as shown in the following diagrams. For
advice on controls that are not featured in this book, please contact
Vokera technical on 0844 3910999
8.2 TYPICAL CONTROL APPLICATIONS
The appliance can be used with the following controls:
twin-channel programmers.
The appliance can be used in conjunction with typical 'S'-Plan
systems and 'Y'-Plan systems.
Please contact Vokera technical should you require further
detailed instruction.
9.1.1 EXTERNAL WIRING LIMITATIONS
Low voltage and High voltage cables must be run separately.
Any external wiring must remain within the limits as detailed:
room thermostat = 30-metres
9.1.2 OUTSIDE SENSOR
The outside sensor can be connected via a controls interface
which enables a connection to be made directly on the PCB at
plug CN6 (see "Fig. 43").
9.2

OTHER DEVICES

Contact the controls manufacturer and/or Vokèra technical
department should you require more specific information on the
suitability of a particular control. Further guidance on the recom-
mended practice for the installation of external controls, can be
found in CHeSS – HC5/HC6 (www.energyefficiency.gov.uk).
IMPORTANT
• The boiler must always be supplied with a permanent 230V
electrical supply.
• The room thermostat connection is low voltage (24 Vdc)
• Do not connect any controls or auxiliary equipment to the
low-voltage terminal strip, other than that approved/supplied
by Vokèra Ltd.
9.3

OTBUS CONNECTION

When an OTBus remote control is connected to the system,
the boiler display shows the following screen:
In particular on the boiler display:
ƒ it is no longer possible to set the boiler OFF/WINTER/sta-
tus (it is set by the OTBus remote control)
ƒ the heating setpoint set on the boiler display is used only if
there are heat requests from the TA and the OTBus remote
control does not have a request if the parameter:
ƒ P3.11 = 1
or
ƒ P3.11 = 0 and the jumper on 1-2pin of X 21 is closed.
ƒ to activate the COMBUSTION CHECK function with an
OTBus remote control connected, you must temporarily
disable the connection by setting the parameter P8.03 = 0.
Remember to reset this parameter once the function has
finished.
We can see that it is not possible, with the OTBus remote
control connected, to change the values of the parameter
P4.12 and P4.23 from 0 to 1.
44
Fig. 41
BE11
NO
NC
C
BE11
NO
NC
C
Fig. 42