Parameters
only if parameter P1.05 = 1
P4.16
MAX CH SET
P4.17
MIN CH SET
P4.18
WEATHER COMP ENABLE
P4.19
WEATHER COMP CURVE
P4.20
NIGHT COMPENSATION
P4.21
CH CLOCK ENABLE
P4.22
MODE SELECTION
P4.23
ZONE1 ENABLE
P4.24
ZONE1 ADDRESS
ZONE1 HYDRAULIC
P4.25
CONFIG
P4.26
ZONE1 TYPE
P4.27
ZONE1 SET
P4.28
ZONE1 MAX CH SET
P4.29
ZONE1 MIN CH SET
P4.30
ZONE1 OTR
P4.31
ZONE1 OTD CURVES
P4.32
ZONE1 NIGHT COMP
P5
DHW
DHW ENHANCED
P5.11
FUNCTION
P7
SERVICE
P7.06
AUTOSTOP FUNCTION
SERVICE EXPIRY
P7.07
P8
CONNECTIVITY
P8.01
BUS 485 CONFIG
P8.03
OT CONFIG
5.4

STARTING THE BOILER

Ensure that steps 6.1 through to 6.6 have been completed be-
fore supplying the gas and electrical supply to the appliance.
- Position the system's master switch to the "on" position.
If necessary, the interface automatically goes to the clock
menu. On the main screen the icons
ENTER come on while 00:00 is displayed with the first two
digits blinking with a frequency of 0.5 sec ON, 0.5 sec OFF.
To set the time and day follow the following instructions:
ƒ set the hour with the
ƒ set the minutes with the
with B
ƒ set the day of the week with the
segment in line with the day selected blinks, press the
MENU key at the icon
setting. The clock blinks for 4sec and then returns to the
main screen
Scrolling message
AT: MIN CH SET - 80.5
BT: MIN CH SET - 45.0
AT: 40 - MAX CH SET
BT: 20 - MAX CH SET
0 / 1
1.0-3.0
0.2-0,8
0 / 1
DON'T MODIFY
DON'T MODIFY
0 / 1
1 - 6
0 / 1
0 / 1
ZONE1 MIN CH SET -
ZONE1 MAX CH SET
AT: ZONE1 MIN CH SET - 80,5
BT: ZONE1 MIN CH SET - 45,0
AT: 40 - ZONE1 MAX CH SET
BT: 20 - ZONE1 MAX CH SET
0 / 1
1.0-3.0
0.2-0.8
0 / 1
0 - 255 (Contact Vokera Technical for further advice)
0 / 1 / 2
0 / 1
,
,
and
and
arrows, then confirm with A
and
arrows, then confirm
and
arrows. The
Enter
to confirm the time and day
Value
AT
BT
AT
BT
NOT AVAILABLE ON THIS MODEL
refer to AUTOSTOP funcition
ƒ to exit the time programming without saving the modified
values just press
NOTE: It is possible to change the TIME and DAY settings
also later by accessing the P1.02 parameter in the P1 menu,
or by pressing the A+C keys for at least 2sec.
A
+
and
ƒ If you need to set the language, select the menu P1 and con-
firm your choice using
ƒ Use the arrows to display parameter P1.01, then enter the
submenu by pressing
ƒ Use the
and
– see " "5.3 SETTINGS MENU TREE STRUCTURE"" . To
confirm your choice, press
Password
Value set
level
in the factory
80.5
INSTALLER
40
INSTALLER
INSTALLER
0
INSTALLER
2.0
INSTALLER
0
INSTALLER
0
INSTALLER
0
INSTALLER
0
INSTALLER
1
INSTALLER
0
INSTALLER
0
USER
40 - 80.5
INSTALLER
80.5
INSTALLER
40
INSTALLER
0
INSTALLER
2.0
INSTALLER
0
0
0
52
SERVICE
0
SERVICE
1
.
+
RESET
MENU
.
.
buttons to set the desired language
Enter
.
Personalised
values
C
25