Riello Residence PRO 32 KIS User's Information Manual
Riello Residence PRO 32 KIS User's Information Manual

Riello Residence PRO 32 KIS User's Information Manual

Hide thumbs Also See for Residence PRO 32 KIS:

Advertisement

Quick Links

Residence PRO 32 KIS
USER'S INFORMATION MANUAL
9
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids or other combustible
materials in the vicinity of this or any other
appliance. To do so may result in an explosion
or fire.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
This manual should be maintained in legible
condition and kept adjacent to the boiler or
in a safe place for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Residence PRO 32 KIS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Riello Residence PRO 32 KIS

  • Page 1 Installation and service must be performed by a qualified installer, service agency or the gas supplier. This manual should be maintained in legible condition and kept adjacent to the boiler or in a safe place for future reference. Residence PRO 32 KIS USER’S INFORMATION MANUAL...
  • Page 2: Table Of Contents

    CONTENTS 1 KEY TO SYMBOLS ......3 2 WARNINGS....... . 3 GENERAL WARNINGS .
  • Page 3: Key To Symbols

    1 KEY TO SYMBOLS The following instructions must be observed − The boiler must only be used for its designated purpose, observing the Installation Instructions. PAY ATTENTION TO THESE TERMS − Only use the boiler in combinations and with the accessories DANGER = Indicates the presence of immediate hazards which will and spare parts listed.
  • Page 4 POUR VOTRE SECURITE LISEZ FOR YOUR SAFETY READ BEFORE OPERATING AVANT DE METTRE EN MARCHE WARNING: AVERTISSEMENT: If you do not follow these instructions exactly, Quiconque ne respecte pas à la lettre les a fire or explosion may result causing property damage, instructions dans la présente notice risque de déclencher un incendie ou personal injury, or loss of life (death).
  • Page 5: Product Receipt

    Goods Receipt number will not be accepted. All returned goods are subject to a restocking charge. Written permission must be obtained through a local Riello distributor and must be obtained by your qualified service technician. Contact your installing/service contractor to initiate a claim. Do not contact Riello S.p.A.
  • Page 6: Structure

    STRUCTURE Filling tap Condensate Trap Backflow preventer valve 4 Drain valve 5 Low Water Cutoff 6 Gas valve Injector 8 DHW sensor 9 Water Temperature High Limit 10 Supply sensor 11 Return sensor 12 Primary Heat exchanger 13 Flame sensor 14 Manual air vent hose 15 Manual upper air vent valve 16 Flue temperature sensor...
  • Page 7: Boiler Front Control

    BOILER FRONT CONTROL Display Icons 136°F MODE MENU SOME OF THE ICONS SHOWN ON THE CONTROL RESET DEVICE SCREEN AT THE START-UP PHASE MIGHT NOT BE AVAILABLE DURING FUNCTIONNING. THIS DEPENDS ON YOUR BOILER CONFIGURATIONS The knob allows for the domestic hot water setpoint adjustment. adjustment It also allows you to switch from one step to another and change the value of the selected parameter within the PROGRAMMING menu.
  • Page 8: Before Switching On

    (~72°F/ 22°F) - Display functionalities: all icons available and sliding the - Then press the “MODE/OK” button repeatedly to select CH or “RIELLO” text will appear. Press the “MODE/OK” button in order CH/DHW mode to stop the display testing RIELL 136°F...
  • Page 9: Adjusting The Heating Water Temperature Without An Outdoor Temperature Sensor Connected

    4.8 ADJUSTING THE HEATING WATER TEMPERATURE WITHOUT AN OUTDOOR TEMPERATURE SENSOR CONNECTED 136°F When there is no outdoor temperature sensor, the boiler operates at a fixed setpoint. If the central heating mode is active, to adjust the central heating temperature rotate the MODE MENU knob until the “...
  • Page 10: General Safety

    4.11 GENERAL SAFETY Water temperatures over 125°F (52°C) can cause instant 136°F severe burns or death from scalds. When supplying general purpose hot water, the recommended initial setting for the temperature control is 120°F (49°C). Safety and energy conservation are factors to be considered MODE MENU when setting the water temperature on the thermostat.
  • Page 11 E020 CONF. MODE MENU MODE MENU RESET RESET WARNING: If in the “Start-up Phase” and the sliding message ““WAIT COMM.” persists, contact a qualified service agency. NOTICE: If communication between SC07 front control and boiler is lost, “COMM.LOST” appears on the display: contact a qualified service agency.
  • Page 12: How To

    5 HOW TO... HOW TO SHUT DOWN THE SYSTEM FOR LONG PERIODS HOW TO INCREASE THE SYSTEM PRESSURE If the Residence PRO boiler is not used for a long time, the following operations must be carried out: The system pressure must be checked periodically to ensure the - set the status of the boiler to OFF by pressing the “MODE/OK”...
  • Page 13: What If

    6 WHAT IF ... 7 MAINTENANCE SUGGESTED MINIMUM MAINTENANCE SCHEDULE WHAT IF I SUSPECT A GAS LEAK Regular service by a qualified service agency and maintenance If you suspect a gas leak, turn off the gas supply at the gas meter must be performed to ensure maximum operating efficiency.
  • Page 14: Annual Servicing Check List

    Gas and Propane Installation Code. Failure to do so may result in substantial property damage, severe injury or death. WARNING: This document is intended as a guideline only, the Riello Residence PRO 32 KIS US/CAN Installation & Operations Instructions For Contractors must be read and followed in its entirety. Failure to do so may result...
  • Page 15: Commonwealth Of Massachusetts

    8 COMMONWEALTH OF MASSACHUSETTS IMPORTANT INSTRUCTIONS FOR THE COMMONWEALTH OF MASSACHUSETTS The Commonwealth of Massachusetts requires compliance with (b) EXEMPTIONS regulation 248 CMR 4.00 and 5.00 for installation of through – The following equipment is exempt from 248 CMR 5.08(2)(a)1 the –...
  • Page 16: Warranty

    Company) warrants to the original purchaser or original For Contractors (service records or proof of maintenance user that all RIELLO GAS FIRED WALL HUNG BOILERS sold by it and documentation are required). all parts thereof are free of defects in material or workmanship −...
  • Page 17 ...
  • Page 18 ...
  • Page 20 NORTH AMERICAN DISTRIBUTOR: Evergreen Products International Inc. 1815 Sismet Rd. Mississauga, ON L4W 1P9 RIELLO S.p.A. CANADA Via Ing. Pilade Riello, 7 - Technical Support Hotline: 1.844.387.4663 37045 - Legnago (VR) - Email: info@egproductsolutions.com Italy Professional Resources: egproductsolutions.com The Company is constantly working to perfect all of its production processes, therefore the aesthetics and size, technical data,...

Table of Contents