¢ UTY-RSNYM
 Button name and function
During address setting mode, indoor unit reject the any operation command from remote controller.
Function number
Refer to Function details
Remote controller address
FAN button
Each time this button is
pressed, the fan setting
changes among "Remote
controller address," "Function
number" and "Setting number."
 Function setting procedure
1.
Connect the power supply of the outdoor unit.
2.
Switch to the function setting mode.
To enter the function setting mode, hold down the 3 buttons of SET TEMP.
and FAN at the same time for 5 seconds or longer.
3.
Press the FAN button.
The Function number indicator flashes. Then, press either the SET TEMP.
SET TEMP.
1-4. Indoor unit (setting by simple remote controller)
button to set up the function number.
Function setting mode initial display
Function number
- (05-32) -
Setting number
Refer to Function details
START/STOP button
Transmits function setting
SET TEMP. " " and " " button
Switches the various numbers.
, SET TEMP.
button or the
1. Function settings (for indoor unit)