Economy Operation; Powerful Operation; Fresh Air Control (For Other Than 07-14Kmtb And Kmcc Series Wall Mounted Type) - Fujitsu ASYG07-14KGTF Service Manual

Table of Contents

Advertisement

7-5. ECONOMY operation

The ECONOMY operation starts by pressing ECONOMY button on the remote controller.
The ECONOMY operation is almost the same operation as below settings.
Mode
Target temperature

7-6. POWERFUL operation

¢ Wall mounted and Ceiling types
The POWERFUL operation starts by pressing POWERFUL button on the remote controller.
The indoor unit and outdoor unit operate at maximum power as shown in the table below.
Compressor frequency
Fan mode
Horizontal louver setting
Release condition:
• Cooling/Dry
Room temperature ≤ Setting temperature -0.5°C or Operation time has passed 20 minutes.
• Heating
Room temperature ≥ Setting temperature +0.5°C or Operation time has passed 20 minutes.
¢ Floor type
The POWERFUL operation starts by pressing POWERFUL button on the remote controller.
The indoor unit and outdoor unit operate at maximum power as shown in the table below.
Compressor frequency
Fan mode
Horizontal louver setting
Release condition:
• Cooling/Dry
Room temperature ≤ Setting temperature -1.5°C or Operation time has passed 20 minutes.
• Heating
Room temperature ≥ Setting temperature +1.5°C or Operation time has passed 20 minutes.
7-7. Fresh air control (For other than 07–14KMTB and KMCC
series wall mounted type)
The fan motor for Fresh Air is operated in synchronization with the indoor fan operation as below.
7-5. ECONOMY operation
Setting temperature +1°C
Cooling
Dry
Heating
Cooling
Dry
Heating
Operation
Fan motor
(Indoor unit)
Stop
Operation
Fan motor
(for Fresh Air)
Stop
Cooling/Dry
Wall mounted type
6
- (04-70) -
Heating
Setting temperature -1°C
Ceiling type
Maximum
POWERFUL
3
5
Maximum
POWERFUL
3
5
7. Various control

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents