Fujitsu ASYG07-14KGTF Service Manual page 347

Table of Contents

Advertisement

¢ Ceiling type
• Rotation number range of compressor
– Model: AOYG24KBTA3
Model name
ABYG18KRTA
• Compressor control based on room temperature
¢ Floor type
• Rotation number range of compressor
– Models: AOYG18KBTA3 and AOYG24KBTA3
Model name
AGYG09–14KVCA
• Compressor control based on room temperature
1-3. Dry operation
Outdoor temperature zone
Room temperature drops
X zone
Ts+0.5°C
J zone
Ts
-1.5°C
Y zone
Outdoor temperature zone
Room temperature drops
X zone
Ts+0.5°C
J zone
Ts
-1.5°C
Y zone
- (04-17) -
Operating rotation number
X zone
J zone
Y zone
Room temperature rises
Ts+1.5°C
Ts-0.5°C
Ts: Set temperature
Operating rotation number
X zone
J zone
Y zone
Room temperature rises
Ts+1.5°C
Ts-0.5°C
Ts: Set temperature
Unit: rps
46
46
0
Unit: rps
54
54
0
1. Rotation number control of compressor