(4) Lead the connection tubing(liquid pipe and gas pipe) through the hole into the wall, or connect piping and wiring
of indoor unit(check the number of wiring terminals of indoor and outdoor units and connect terminals with the same
number and color), and then put the connection tubing and the connecting line through from the inside wall for the
connection with outdoor unit.
The operation for changing the direction of drain pipe
The N high wall indoor units are right side drainage
when out of factory, but you can change it to left side
A
drainage
Opertion method as follows:
Step 1: Remove the screw that secures the right side
drain pipe, then unplug the drain pipe
D
Step 2: Unplug the rubber plug on the drain hole on the left side of the unit
Step 3: Install the drain pipe removed from the right side onto the drain hole of the left side, fixed with the screw
Drain pipe