Possible Malfunctions
Malfunction
Insufficient cooling
efficiency.
The compressor
does not switch off
automatically.
The appliance
operates loudly.
700336
Possible Cause
Direct sunlight or heat
sources in immediate vicinity.
Poor air circulation around
the appliance.
Door is not closed
properly or it has been
opened for too long.
Damaged or deformed door
seal.
Blocked/covered air inlet
and/or air outlet.
Too little clearance between
objects inside the appliance
or too many objects in the
appliance.
Overfilled appliance.
Door is opened for too long.
The appliance is not placed
on even surface.
Appliance touches walls or
other objects.
Solution
Move the appliance away
from heat sources.
Keep sufficient clearance
from walls or other objects.
Close the door tightly; limit
the door opening time to
minimum.
Contact the supplier.
Make sure the air inlet and
air outlet are free.
Provide for sufficient
clearance between objects
inside the appliance;
remove the excess of
objects.
Remove the excess of
objects.
Limit the opening time of
doors to minimum.
Place the appliance on
even surface.
Keep sufficient clearance
from walls or other objects.
EN