CHECKING/CLEANING THE AIR FILTER

For proper performance and long life, keep air
filters clean.
1. Unscrew the air filter connection screw located
at the bottom of the air filter cover. Remove the
cover and set aside (Fig.13).
2. Remove the filter elements (Fig.14).
3. If the filter elements are dirty, clean with warm,
soapy water. Rinse and let dry.
4. Apply a light coat of engine oil to the elements,
then squeeze it out.
5. Replace the elements in the air filter unit.
6. Replace the air filter cover and tighten the air
filter connection screw.
NOTE: Do not run the generator without the air
filter. Rapid engine wear will result.

SPARK PLUG MAINTENANCE

The spark plug must be properly gapped and free
of deposits in order to ensure proper engine
operation. To check:
1. Remove the spark plug cap (Fig.15 & 16).
2. Clean any dirt from around base of spark plug.
3. Remove spark plug using wrench provided.
4. Inspect spark plug for damage, and clean with
a wire brush before reinstalling. If insulator is
cracked or chipped, spark plug should be
replaced. Make sure electrode gap is 0.60mm-
0.80mm.
NOTE: If replacing, use the following
recommended spark plug: F6TC.
5. Screw spark plug back by hand, avoid
damaging threads of the cylinder.
6. Put the spark plug back in position and use the
spark plug wrench to tighten it. If spark plug is
new, use 1/2 turn to compress washer
appropriate amount. If reusing old spark plug,
use 1/8 to 1/4 turn for proper washer
compression.
7. Replace spark plug cap.
MAINTENANCE